Data Logger Gas Detector Gasman II (EEx ia (d) IICT3/T4) |
||||||
The gas detector Gasman ll is highly effective device for protection against a single toxic, oxygen or flammable gas or vapour. This gas detector is often used to protect staff in gas and water utilities, oil platforms and petrochemical environments. |
||||||
- Compact & lightweight gas detector, making it easy to use the device all day |
|
|||||
Technical specifications: | ||||||
Gas type | Range | Alarm @ | ||||
Flammable gas | 0...100% LEL | 20% LEL | ||||
Hydrogen sulphide | 0...50, 0...100, 0...250 ppm | 10 ppm | ||||
Carbon monoxide | 0...500 ppm | 30 ppm | ||||
Sulphur dioxide | 0...10 ppm | 2 ppm | ||||
Chlorine | 0...5 ppm | 0.5 ppm | ||||
Nitrogen dioxide | 0...10 ppm | 2 ppm | ||||
Phosphine | 0...5 ppm | 0.5 ppm | ||||
Ammonia | 0...50 ppm | 25 ppm | ||||
Hydrogen cyanide | 0...25 ppm | 10 ppm | ||||
Hydrogen | 0...999 ppm | 100 ppm | ||||
Oxygen | 0...25% | 19% and 23% v/v | ||||
Sensors (sensors are changeable) |
duration time (T90) | sensor life | ||||
Methane | 20 sec. | 5 years | ||||
Toxic | 20 sec. | 3 years | ||||
Oxygen | 10 sec. | min. 1 year | ||||
Detector |
||||||
Data logger: | adjustable sample rate; 30 ... 3000 hrs | |||||
Acoustical alarm: | - 85 dB(A) @ 1 m, tone rate adjustable - confidence blip - triple blip every 10 sec. if battery is low |
|||||
Visual alarm: | ultra bright red flashing LED pair display indicates alarm types |
|||||
Vibration alarm: | single frequency vibration at all alarm levels | |||||
Display: | 7 segment high contrast LCD 10 mm character height, backlight symbols for peak hold, low batt, zero mode, calibration mode, alarm 1, alarm 2, 15 min TWA, 8 hour TWA |
|||||
Housing: | ABS, IP 66 | |||||
Power supply: Toxic gas and oxygen models Flammable gas models |
3 x AA alkaline nickel-hybrid (rechargeable) |
|||||
Battery life: Toxic gas and oxygen models Flammable gas models |
3000 hrs 12 hrs (16 hrs recharge time) |
|||||
Total dimensions: | 130 x 60 x 30 mm | |||||
Net weight: | 210 g | |||||
Operating range temperature: |
-20 ... + 50 °C, -4 ... 122 °F |
|||||
Humidity: |
0 ... 95 % rH (non condensing) |
|||||
Safety/protection codes: |
EEx ia (d), IIC T3/T4 |
|||||
RF radiation: |
EN 50081-2 (immunity: EN 50082-2) |
|||||
Delivery content: |
||||||
Additional component: |
![]() |
|||||
![]() |
![]() |
|||||
Contact: |
||||||