Home | Data Protection | Gen. Terms | Calibrations | Service | About PCE Inst. | Contact | |||
PCE Instruments UK Ltd. PCE Americas Inc. |
|
|||||||||
Analytical Balances |
|||||||||
- PCE-BS series Analytical Balances |
|||||||||
- PCE-HB series Analytical Balances |
|||||||||
- PCE-HB-M series Analytical Balances |
|||||||||
- PCE-BT series Analytical Balances |
|||||||||
- PCE-PM...T series Analytical Balances |
|||||||||
- PCE-LSM series Analytical Balances |
|||||||||
- PCE-LSZ 200C series Analytical Balances |
|||||||||
- PCE-LS series Analytical Balances |
|||||||||
- PCE-ABZ 100C series Analytical Balances (analytical balances at a good price and of good quality, 0 to 100 g/0.1 mg; RS-232 port) |
|||||||||
- PCE-ABZ 200C series Analytical Balances |
|||||||||
- PCE-AB-C series Analytical Balances |
|||||||||
- PCE-AB series Analytical Balances |
|||||||||
Not all the previously mentioned balances can be used as classic analytical balances. We made such a selection of balances because they fit within the scope of analysis. Normally all analytical balances have a sensitivity of less than 0.1 mg. The result indicated in the document of analysis is the value of at least two results with a sufficient repeatability (factor r). Electronic analytical balances frequently have an enclosure which protects from oscillations due to the wind breath, calibration programmes and shock absorbers that can eliminate sudden movements. Our balances have all the fundamental prerequisites, depending on the model, and multiple components:
|
|||||||||
Analytical balances are frequently used in the industrial sector as well as in quality control or product development. These balances are also used in research and development, in clinics, technical colleges and universities, mainly in their laboratories. Analytical balances are high quality devices and are accurate with resolution of 0.1 mg. A good example is the PCE-AB series. The PCE-VXI 60/220 is a scale with a reading capacity of only 0.01mg. If you need balances with a resolution of 0.001 mg, you should consider that analytical balances with this resolution also notice evaporation of liquids. Furthermore, they have protection against wind breath and have a level to ensure they are portioned correctly. In the following image you can see balances with an internal adjustment weight. This weight is used for making automatic adjustments to analytical balances. Adjustment is done automatically, for example every two hours or if temperature changes of ±1°C occur. This ensures a consistent high level of accuracy. Once the balances are turned on, they perform an internal check of all the functions which is initiated by an electronic component in the device and an adjustment is made by the internal adjustment weight. ISO certificate with calibration document or verification which meets DIN ISO 9000 can be ordered. |
|||||||||
If you wish to view or print a selection of analytical balances from our catalogue, click PDF symbol |
You are currently at: Home/measuring instruments and test equipment/balances/Analytical Balances |
If you have any questions, call our offices on: |