BOD meter OxiDirect
BOD
meter to determine biochemical oxygen demand / direct collection of samples /
precise and immediate display of the BOD values in mg/l / measurement interval
selectable / data storage / comfortable handling / RS232 interface / eco-
friendly
|
The
BOD meter OxiDirect is a device that is designed to determine the biochemical
oxygen demand, called B.O.D. By means of the BOD meter the samples can be taken
without further ado, and the BOD values are displayed in real-time speed,
precisely in mg/l. Each BOD meter features, depending on the edition, six or
twelve sample containers. The handling of the BOD meter is very comfortable and
the measurement period is selectable for a period of 1 to 28 days. The amount of
oxygen expended for the catabolism of organic substance in water samples is
called the biochemical oxygen demand. By measuring the BOD, biodegradable
substances in water can be determined as well. Therefore the BOD is an important
factor to determine the effect of industrial waste and that from private
household on the water quality in sewage treatment plants and their receiving
waters. The BOD meter OxiDirect allows an exact and comfortable determination
of the BOD, following the respirometric principle. Therefore the amount of oxygen
that is already metabolized, can be calculated by recording the pressure
reduction inside the sealed BOD meter. Due to the fact that the BOD value of the
sample correlates with its pollution by organic substances, and by that the
value might vary, the BOD meter is customized for the sample volumes listed below, depending on their measurement range. This results in a total
measurement range of 0 ... 4,000 mg/l. The BOD meter can be applied on sewage,
for determining bilogical activity rates, on clarification plants, analytic
laboratories, in research and development. If there are any questions about this BOD meter
OxiDirect , please have a look at the technical specification
below or call: UK customers +44(0) 23 809 870 30 / US customers +1-410-387-7703.. Our engineers and
technicians will gladly advise you regarding the oxygen
meters or any
other products in terms of regulation
and control, or scales
and balances of PCE
Instruments.
|
|
|
-
6 or 12 sample containers
- Simplified sample drawing
- Measuring period variable
|
-
Immediate display of BOD level in mg/l
- RS232 interface
- Total measurement range of 0 ... 4,000 mg/l
|
General
Technical Specifications of the BOD meter OxiDirect
|
Measurement
principle
|
respirometric, quicksilver-free, electronic
pressure sensor
|
Measurement ranges (mg/l O2]
|
0 ... 40, 0 ... 80, 0 ... 200, 0 ... 400, 0 ...
800,
0 ...2000, 0 ... 4000
|
Accuracy
|
0.5 % of final value from measurement range at
20°
|
Application
|
BOD5, BOD7, OECD 301 F...
|
Display
|
BOD [mg/l], 4-digit, 7-segment LED
|
Parameters
|
BOD measurement range, volume, period, time of
measurement
|
Measurement interval
|
eligible between 1 and 28 days
|
Autom. data storage
|
up to 28 measurement values, depending on
measurement interval
|
Memory interval
|
- hourly (1day)
- every two hours (2 days)
- daily (3-28 days)
|
Automatic start
|
- after tempering the samples
- can be turned-off
|
Power Supply
|
3 alkaline batteries
|
Battery lifetime
|
1 year, if common use of BOD5 meter
(maximum of one read-out per day), early warning in case the battery is down
|
Interface
|
RS232 for printer or computer connection
|
Clock
|
Real-time clock
|
IP Code
|
IP54
|
Diameters
|
375 x 195 x 230 mm (incl. mixing unit)
|
Weight
|
Device with bottles: approx. 3850 g
Completely incl. mixing unit: approx. 5750 g
|
Measurement
range and sample volume
|
The
BOD level of a sample depends on its pollution with organic substances and can
be extremely variable. Thus the BOD meter can be configured to the sample
volumes below, depending on the measurement range.
|
Measurement
range BOD mg/l
|
Sample
volume ml
|
0
... 40
|
428
|
0
... 80
|
360
|
0
... 200
|
244
|
0
... 400
|
157
|
0
... 800
|
94
|
0
... 2000
|
56
|
0
... 4000
|
21.7
|
Mechanism
of BOD meter OxiDirect
|
During
the BOD determination the bacteria inside the sample consume the resolved
oxygen. That difference in oxygen of the water compartment is then replanished by the
oxygen from the gas compartment of
the sample container. The resulting carbon dioxide emerging from the
metabolism inside the water compartment and given to the gas compartment enters a chemical reaction
with the potassium hydrate solution inside the tubular of the BOD meter. By
that it is withdrawn from the gas compartment of the sample container. The
ultimate result is a decrease of pressure. That decrease of pressure is
linear proportional to the BOD level and is measured by the BOD sensor. The
BOD value is then immediately displayed in mg/l.
The recorded BOD values can be displayed in mg/l anytime, without the need of
any additional calculation. Thus e.g. a collection of data over a weekend can
be evaluated in the following week without further ado. The measurement
interval is eligible within 1 to 28 days. BOD measurements commonly cover a
period of 5 days. Short-time measurements can be useful for the purpose of
research. Measurements covering a period of time are e.g. demanded for OECD
determinations.
|
Delivery content
of the BOD meter OxiDirect with 6 sensors
|
1
x BOD meter OxiDirect with 6 sensors and control unit with batteries
1 x inductive magnet stirrer with adapter,
6 x sample containers
6 x tubulars
6 x stirring staffs
1 x piston to measure overrun 157 ml,
1 x piston to measure overrun 428 ml,
1 x bottle potassium hydrate solution 50 ml
1 x bottle nitrification inhibitor 50 ml
1 x instruction manual
|
Delivery content
of the BOD meter OxiDirect with 12 sensors
|
1
x BOD meter OxiDirect with 12 sensors and control unit with batteries
1 x inductive magnet stirrer with adapter,
12 x sample containers
12 x tubulars
12 x stirring staffs
1 x piston to measure overrun 157 ml,
1 x piston to measure overrun 428 ml,
1 x bottle potassium hydrate solution 50 ml
1 x bottle nitrification inhibitor 50 ml
1 x instruction manual
|
Delivery content of BOD meter OxiDirect
|
Optional equipment for BOD meter Oxidirect
|
Optional
Equipment of the BOD meter OxiDirect
|
Article
|
Ref.
Number
|
BOD
sensor
|
2
44 44 30
|
BOD
sample bottle (brown glass, 500 ml)
|
41
86 44
|
BOD
sample bottle (brown glass, 500 ml, set of 6 bottles)
|
41
86 45
|
Connecting
cable for computer (serial 9-pole)
|
2
44 44 40
|
Inductive-stirring
system (for 6 samples, 100-240 V / 50-60 Hz)
|
2
44 44 52
|
Magnetic
stirring staff
|
41
86 37
|
Stirring
staff remover
|
41
86 38
|
Rubber
tubular
|
41
86 36
|
Chemicals:
|
Potassium
hydrate solution (45 %, 50 ml)
|
2
41 86 34
|
Nitrification
inhibitor (N-ATH, 50ml)
|
2
41 86 42
|
Measurement
piston (21.7 ml)
|
41
86 64
|
Measurement
piston (56 ml)
|
41
86 55
|
Measurement
piston (94 ml)
|
41
86 56
|
Measurement
piston (157 ml)
|
41
86 57
|
Measurement
piston (244 ml)
|
41
86 58
|
Measurement
piston (360 ml)
|
41
86 59
|
Measurement
piston (428 ml)
|
41
86 60
|
Complete
set of pistons
|
41
86 54
|
Test
set (BOD CM test tablet, box with 8 tablets)
|
41
83 28
|
Incubator
for continuous tempering of various objects
Applications
-BOD determination
- microbiological research
- Food industry
- Creamery
- Laboratories
- Research facilities
- Universities
|
|
-
Display with background lights
- +2 ... +40 °C
- Settings in 0.1 °C steps
- 20 °C BOD determination
- 4 °C storage of sewage samples
- 25 °C enzyme activity (TTC test)
- 37 °C bacterial count The
unit for temperature regulation fulfills the EMC-directives according to IEC
61326: Electrical devices for measurement, monitoring and laboratorial
use.
|
|
|
|
Here you will find an overview of all the
measuring instruments available at PCE Instruments. |
Contact: PCE Instruments UK Limited
Unit 11 Southpoint Business Park
Ensign Way, Southampton
United Kingdom, SO31 4RF
Phone: +44(0) 23 809 870 30
Fax: +44(0) 23 809 870 39
|
Contact: PCE Americas Inc.
1201 Jupiter Park Drive, Suite 8
Jupiter 33458 FL
USA
Phone: +1-410-387-7703