The
explosives detector GAZEX is designed to measure explosive gas limits in
hazardous environments. The explosives detector proves itself as a handy and
small device to measure flammable gasses with a maximum of three measuring
ranges. There are nowadays many production areas, in which flammable
gasses are produced, stored or burned. Those can be monitored by the
explosives detector, since most of these gasses are inodorous and by that might
not be perceptible for humans without any devices. Due to the fact, that even little amounts of
those gasses might lead to explosions, it is important to detect those amounts by means of
the explosives detector GAZEX. The explosives detector works by measuring
the recalescence and heat conductivity. Due to a single-key-navigation the
explosives detector is a device that is easy to handle, but at the
same time, it covers a large application range. Thus the display of the
explosives detector can be easily set up. The explosives detector displays
limits, current values and battery state. The explosives detector has to be charged
at the docking station what is included in the delivery. In case there are more than one
devices to charge at their docking station, a maximum of ten of those stations
can be operated at the same time by connecting them and using only one adapter
to charge them simultaneously. Typical application ranges of the explosives detector
are mainly gas supplies, heating units, chemical industries, fire fighting,
refineries and any other conditions, under which explosive gasses might emerge. If there are any questions about this Explosives
Detector GAZEX , please have a look at the technical specification
below or call: UK customers +44(0) 23 809 870 30 / US customers +1-410-387-7703.. Our engineers and
technicians will gladly advise you regarding the gas
detectors or any
other products in terms of regulation
and control, or scales
and balances of PCE
Instruments.
|
|
|
-
Low
weight
- Display with background lights
- Up to three measuring ranges (ppm, UEG, VOL)
|
-
Reasonable price
- Optical and acoustic alarm
- Docking station included in delivery
|
Technical specifications
of
the Explosives Detector GAZEX - LEL
|
Measuring
range
|
0
...100 Vol. % LEL methane
|
Measuring
method
|
LEL
recalescence (pellistor)
|
Technical specifications
of
the Explosives Detector GAZEX - LEL/Vol. %
|
Measuring
range CH4 methane
|
0
... 100 % LEL
0 ... 100 % Vol.
|
Measuring
method
|
LEL
recalescence (pellistor)
VOL heat conductivity
|
Technical specifications
of
the Explosives Detector GAZEX - LEL / Vol. % / ppm
|
Measuring
range
|
0
... 10000 ppm
0 ... 100 % LEL
0 ... 100 Vol.-%
|
Measuring
method
|
ppm
recalescence (pellistor)
LEL recalescence (pellistor)
VOL heat conductivity
|
General
Technical Specifications of the Explosives Detector GAZEX
|
Response
time T90
|
≤20
sec.
|
Sample
collecition
|
Diffusion
or hand pump
|
Measuring
method
|
continuous
measurement
|
Alarm
thresholds
|
2
alarms: 20 % and 40 % LEL
|
Key-functions
|
3-way
button switch
|
Display
|
LCD
|
Alarm
types
|
visual,
acoustic and vibration
|
Enclosure
|
ABS
and elastomer
|
Power
Supply
|
Lithium-
Ion battery
|
Operation
time
|
Battery
≥ 15 hrs.
|
Charging
time for battery
|
4.5
hrs
|
Battery
monitoring
|
acoustic,
optical alarm, plain text display
|
Operation
monitoring
|
self
test at start
|
Navigation
|
Single-key-navigation
|
Operation
temperature
|
-20
... +40 °C
|
Storage
temperature
|
-30
... +50 °C
|
Air
humidity
|
15
... 95 % rH
|
Weight
|
119
g
|
Measurements
|
139
x 50 x 28.2 mm (W x D x H)
|
Protection
type
|
IP
67 (waterproof)
|
Ex-Prevention
|
CE
INERIS 02 ATEX 0060 II 1 G EEx ia IIC T4
|
Display
function / Measuring technology
|
EN
30079-291: 2007; EN 50271
|
Examples
of Application
|
|
Here
you can see the Explosives Detector GAZEX at the docking station during
calibration
|
Delivery content
of the Explosives Detector GAZEX
|
1
x explosives detector GAZEX
1 x docking station to charge and configure
1 x crocodile clip
1 x 3.6 V lithium battery
1 x instruction manual
|
|
Optional
Equipment of the Explosives Detector GAZEX
|
Gadget
for manual suctioning with customized 3 m test tube, hand pump, flow monitor,
water barrier (0100-050)
Metal case type 1 to carry around and store one explosives detector with
equipment
(0100-018)
|
General
Information regarding the Explosives Detector GAZEX
|
The
measuring principle of recalescence can be used for LEL- and leakage- measuring. Therefore the measured gas is to be
conducted to a heated measuring element of the explosives detector, where it
is burned catalytically. During its inflammation, the electrical resistance of
the measuring element alternates, induced by the heat-up. That alternation of
the electric resistance of the measuring element is proportional to the
gas concentration, and is measured by the explosives detector. For a
measurement following the principle of heat conductivity, the sampled gas is conducted to a
measuring element, that is heated. Depending on its concentration, the gas
either cools the measuring element down or heats it up, due to
which the electric resistance alternates. Afterwards that change is recorded
by the explosives detector. Thereby the alternation of the electrical
resistance is proportional to its gas concentration.
|
|
|
Similar
products to the Explosives Detector GAZEX:
|
|
Here you will find an overview of all the
measuring instruments available at PCE Instruments. |
Contact: PCE Instruments UK Limited
Unit 11 Southpoint Business Park
Ensign Way, Southampton
United Kingdom, SO31 4RF
Phone: +44(0) 23 809 870 30
Fax: +44(0) 23 809 870 39
|
Contact: PCE Americas Inc.
1201 Jupiter Park Drive, Suite 8
Jupiter 33458 FL
USA
Phone: +1-410-387-7703
Fax: +1-410-387-7714
|