PCE-IT
413/414 Insulation Meter Insulation meter for high tension up to
5,000 volts or up to 10,000
volts
|
The PCE-IT413 insulation meter and the PCE-IT414 insulation meter belong to a series of highly accurate resistance devices that have a 6 digit display. These insulation meters are developed specifically for technical service and for difficult measurement conditions. One of the advantages is a built in protection to avoid errors originating from loss of current. The insulation meter contains a microprocessor and both optical and visual alarms. Factory calibration ensures the most accurate measurements with these insulation meters. This link has an overview of the available insulation meters.
|
|
|
- For professionals - 6 digit LCD - Measurements according to VDE 0413 part 1 - Test tension up to 5000 V (Model: PCE-IT413) and up to 10,000 V (Model: PCE-IT414) - 3 year warranty
|
- Safety standards: IEC-1010-1; CAT III IEC- 1010- 1 EN 61010- 1 - EMV EN 50081- 1 EN 50082- 1 - Very good price/quality relationship |
Technical specifications |
Model
|
PCE-IT413 PCE-IT414
|
DC test tension |
500/1000/2500/5000 V |
1000/2500/5000/10,000V |
Range of measurement |
30 GΩ/500 V 60 GΩ/1000 V 150 GΩ/2500 V 300 GΩ/5000 V |
60 GΩ/1000 V 150 GΩ/2500 V 300 GΩ/5000 V 600 GΩ/10,000 V |
Accuracy |
± 3% |
Potential output |
maximum 1 watt |
Insulation resistance between electrical conduction and the enclosure |
2000 MΩ/2000 V |
Static tension between enclosure and circuit |
700 V AC for a maximum of 1 minute |
AC warning circuit |
for tension > 450 V AC |
Power |
8 batteries (1.5 V) |
Dimensions |
250 x 110 x 190 mm |
Weight |
1.5 kg |
Delivery content: 1 x PCE-IT413 or PCE-IT414 insulation meter, 1 x colour coded silicon test cable, 1 x protective cover for coaxial conductors, 8 x AAA batteries and user manual
|
|
Instructions for measuring across an insulation meter:
- disconnect the power - connect N and PE cables between two points - disconnect the fuse from the device being measured, then connect LS and FI cables and then reconnect the power
- connect measurement cables, phase conductor and PE, and phase conductor and N, then connect the insulation meter and take the measurement. It seems sensible to us to take a measurement between the conductor phase to easily detect damage or aging of the lines. The minimum values of resistance of an insulation meter for measurement of voltage should be 250 V DC 0.25 MΩ, at 500 V DC 0.5 MΩ and at 1000 V DC 1 MΩ.
|
|
|
Here you will find an overview of all the measuring instruments available at PCE Instruments.
|