PCE-IT111
Insulation
Meter Auto
ranging
insulation meter up to 8 GΩ in a compact enclosure
|
The insulation meter detects the resistance of insulation up to 8 GΩ (in auxiliary voltage of 250, 500 and 1000 V). The insulation meter also allows measurement of alternate and continuous voltage up to maximum 950 VDC and 700 VAC, and resistance up to maximum 2 kΩ. It has a transit tester with an integrated acoustic signal. The readings can be stored by pressing a button. The device meets the standards: DIN 57 411 part 1/VDE 0411 part 1, countermeasure for electronic devices (IEC1010-1) and DIN VDE 0413 (insulation meters). The insulation meter comes calibrated from the manufacturer, although there is an optional ISO calibration certificate which can be ordered with the device or when an annual recalibration is required. Definition of the resistance of insulation: The resistance of insulation is the resistance in ohms in lines, cables and electrical installations. It holds significant importance in protecting people against electrical discharges and in preventing damage to materials by passing currents. With the measurement of resistance of insulation it tests and evaluates the condition of the insulation (conductors and enclosures). This link shows an overview of all the available insulation meters which will suit your needs.
|
- 2 line, 16 digit LCD
- Automatic indication of polarity
- Automatic range selection
- Automatic zero reset to prevent errors when using the test cables
- Acoustic signal when there is a discharge in insulation measurements
- Overload protection during a transit test
- Safety function, voltage is maintained for only 10 seconds (can be disabled)
- HOLD function
- Optional ISO calibration certificate
- Protection according to the IEC 1010-1, 700 V CAT III standard
|
PCE-IT11 insulation meter
View or print the user manual
|
Fields of use |
|
Thanks to the multiple functions of this insulation meter, it can be used in many fields:
- Measurements of insulated cables, transformers, motors and insulation in general
- Measurements of high resistance
- Maintenance and repair
- Measurements of dielectrics and polarity
The image to the left shows the isolation meter measuring a motor.
|
Technical specifications |
Measurement ranges |
2 GΩ/250 V 4 G Ω/500 V 8 GΩ/1000 V ACV: 0 to 950 V DCV: 0 to 700 V Ohms: 0.01 to 1999 Ω |
Resolution |
Insulation: 1/10/100 MΩ ACV: 1 V DCV: 1 V Ohms: 0.01/0.1/1 Ω |
Accuracy |
Insulation: ±3% ACV: ±1.5% DCV: ±1.5% Ohms: ±2.0% |
Continuous test voltage |
250/500/1000 V |
Short-circuit current |
4.0 mA |
Display |
2 line, 16 digit LCD |
Power |
8 x 1.5 V batteries |
Operating conditions |
approx. 655 g |
Environmental conditions |
5 to 95% relative humidity/0 to 55°C |
Type of protection / standards |
IEC 1010-1, 700 V CAT III |
Delivery content: 1 x PCE-IT111 insulation meter, 1 x set of test cables with screw fastened clamps, batteries, 1 x carrying case and user manual
|
Optional accessories - ISO calibration certificate For companies that wish to incorporate the calibrator into their set of internal test equipment or for annual recalibrations. The ISO certification includes a laboratory calibration with a test certificate with all the measurement values.
|
|
The measurement of insulation should be performed on any new installation, overhaul, changes or repairs. As can be seen on the image to the right, its essential to test insulation when rewinding and repairing electro-motors. It is necessary to test motors after they have been operating for a period of time, so the measurement of insulation acts as an evaluation of the operating life of the motor, especially when there are adverse climactic conditions. A typical test voltage reading for low voltage motors and transformers is 1000 V.
|
|
|
|