PCE-IT 55
Insulation Tester
CAT III 1000V /
for insulation resistance up to 2000 MΩ
|
The PCE-IT 55 Insulation Tester
determines insulation resistance up to a
maximum of 2000 MΩ (for
auxiliary voltages of 250, 500 and 1000V).
This Insulation Tester also offers the
ability to measure alternate and
continuous currents up to a maximum
750V / 1000V
and resistance up to
2 kΩ. Includes test current
and a warning whistle. Readings can be
stored by pressing a single key. The
device meets with these standards: DIN 57
411 part 1 / VDE 0411 part 1, protective measures for
electronic devices
(IEC1010-1) and DIN VDE 0413 (Insulation
Tester). It
comes calibrated from the manufacturer
and an optional laboratory calibration
and ISO certificate can be ordered
separately for annual recalibrations.
This
link shows an overview of whichever
insulation meter you may need for work.
|
- Meets the
standards: IEC1010-1,
CAT III 1000 V
- Has a large dual, backlit
display
- Individual or prolonged
measurements can be
made by pressing the "lock"
key
- Indicates
overload and battery level
- Auto shut of to conserve
battery power
- Comes ready to use in its own carrying
case
-
optional ISO calibration certificate
PCE-IT 55 Insulation Tester
View or print the user's manual
|
|
Technical
Specifications |
Measurement ranges:
Voltage AC
Voltage DC
Resistance
Insulation
resistance |
0
... 750 V
0 ... 1000 V
0 ... 200 Ω / 200 ... 2000 Ω
0 ... 200 MΩ / 200 ... 2000 MΩ |
Resolution
Voltage AC
Voltage DC
Resistance
Insulation
resistance |
1V
1V
0.1 Ω / 1 Ω
100 kΩ to1 MΩ |
Accuracy Voltage
AC
Voltage DC
Resistance
Insulation
resistance |
±1.2% ±10 digits
±0.8% ± 3 digits
±1.0% ± 2 digits
±3.5% ± 5 digits |
Test voltages |
250V - 200 MΩ
500V - 200 MΩ
1000V - 2000 MΩ |
Test current |
whistle: ≤40 Ω,
test current ≤200mA |
Power |
6
AA batteries |
Operating
conditions |
0
to 40°C / <80% r.h. |
Dimensions |
200
x 92 x 50mm |
Weight |
700g |
Standards |
IEC10101,
CAT III 1000V |
Delivery contents
PCE-IT 55 Insulation Tester, test
cables,
extractable clamp with 1m
cable, 6 batteries, carrying case and user's
manual (see image) |
|
Optional
accessories
- Calibration certificate,
meeting with DIN ISO 9000.
The certification includes a laboratory
calibration and a test certificate
containing all the measurement values. |
|
|
Information
about Insulation Tester
The measurement of insulation should be done for new
installations, upgrades, changes or repairs. It is also
necessary to repeat measurements at pre-determined times
for industrial machinery. In the provate sector, it is
important to periodically check the condition of
installations, in case the insulation value deteriorates
due to aging, climactic conditions or general wear and
tear. |
Value limits to consider
when measuring insulation
- for new installations (dry
spaces): 1000 Ω x V of
the operating voltage (eg. 230V > 230kΩ)
- for new installations (humid
spaces, open air): 500 Ω x V
of the operating voltage
- grounded device: 1000
Ω x V of operating
voltage
- device with insulation
protector:
2 MΩ
- electrical tools: 2 MΩ
- low voltage: 250 kΩ
- electrical meters: 5 MΩ
The values of test
voltages are usually 100V for installations with low
voltages and telecommunication installations, 500V for
installations in buildings and houses and 1000V for low
voltage engines and transformers. |
|
|
Here you will find an overview of all the
measuring instruments available at PCE Instruments. |
Contact:
PCE Instruments UK Limited
Unit 11 Southpoint Business Park
Ensign Way, Southampton
United Kingdom, SO31 4RF
Phone. +44 ( 0 ) 2380 98703 0
Fax +44 ( 0 ) 2380 98703 0 |