PCE-IMS 1 Monitoring System Monitoring
system with large 5-digit display / additional clamping screw / a high quality wooden carrying case is delivered
|
The PCE-IMS 1 Monitoring System is the cheapest solution for monitoring and surveillance as well as for quick, easy and safe domestic automation. The PCE-IMS 1 Monitoring System can also be used in the industrial sector. The PCE-IMS 1 Monitoring System can detect analogue and digital temperature sensors, humidity, access, vibration, smoke, voltage, leakages, gases, movement, level, pressure and others, as well as it can control up to 240 sensors per module and record corresponding values. The PCE-IMS 1 Monitoring System also allows video surveillance through USB or IP camera. All sensors are automatically detected. With the PCE-IMS 1 Monitoring System it is very easy to perform a logic programming that sends messages or images (from USB cameras), SMS, email or ICQ/AIM if limit values are exceeded. Sensors and relays can be placed at some kilometers from the monitoring system by using an intermediate station. The PCE-IMS 1 Monitoring System can also be connected to switches and relays for a domestic automation to check if digital inputs have enough voltage to make the device react. Here you will find an overview of monitoring systems.
|
View or print user manual of the PCE-IMS 1 Monitoring System
|
- Controls up to 240 sensors - Good price and quality - Automatic sensor detection - Switches and relays connection - Alarm through email, Messenger or SMS - USB and IP cameras can be connected - It can be extended to some kilometers - Optional GSM modem - Addressing through web browser - Logic (sensors control automation) - Sensors limit values can be adjusted - Graphic area with background image - DynDns support - User management - Configuration through Drag-and-Drop - Suitable for domestic use - Checking server connection (Ping) - Detailed Log function - Automatic diagram drawing - Alternative HTML version - Automatic adding of FTP records in CSV format - Easy integration - Quick installation - Constant development
|
Go to live demo >>>
In our live demo of the PCE-IMS 1 Monitoring System you can see the system being used to get an idea of the broad functions available in this system.
For more information please do not hesitate to get in contact with us
|
Technical specifications |
Installation |
19" Rack |
IP surveillance |
Web, SNMP, SMS, ICQ, AIM |
Interface
|
Access through any browser but also alternatively with HTML presentation |
Lan
|
Ethernet 10/100 Mbit |
RAM |
32 MB |
ROM
|
8 MB flash |
Alarms |
eSMTP or SNMP Traps, SMS, ICQ, Email |
LED indication
|
4 green LEDs: PWR, ALRM, PRG, ACT, 4 red LEDs: On/Off, relay outputs |
Input voltage
|
12 V 10 W |
Switching power for each relay |
10 A 250 V AC, 10 A 30 V DC |
Dimensions |
440 x 44 x 110 mm |
Weight |
approx. 2 kg |
Connections |
USB 2.0 (Webcam) 8 x single protected 6P6C ports for different sensors, 2 x 6P4C for the connection of a maximum of 20 digital sensors, 16 free-power contacts (measurement of the status), RS-232 for the preventive servers log-off |
Delivery content Mains component, user instruction CD, warranty, technical sheet, 4 shelf-adhesive rubber feet, 3 connectors with terminal strips TBW-5-6P |
Browser control software |
Using the software, which is installed in the PCE-IMS 1 Monitoring System, you can perform any configuration in your PC through a web browser, such as connect relays or switches both manually or automatically and also monitor with a camera the diverse sensors.
|
PC software |
With the PC software of the automation system it is possible to automatically execute commands on a computer, for instance, to switch off the server when a certain temperature is reached or if there are major power surges. In order to use the software with your computer RS-232 port or USB adpater is required which is available with our PCE-IMS 1 Monitoring System. |
Expansion modules |
All expansion modules of the PCE-IMS 1 Monitoring System can be placed up to 1 km from the main unit. The connection is carried out by a Cat 6 cable with RS-485. The PCE-IMS 1 Monitoring System drives and records expansion modules monitoring per station. |
Contact module
|
This module has a contact strip This contact strip allows the user to assess and monitor switches and other On/Off conditions to which the PCE-IMS 1 Monitoring System can react according to preliminary indications: Weight: 0.4 kg, Dimensions: 145 x 30 x 62 mm. Delivery content: User manual, technical information, UTP Patch cable (1 m), 4 pins with terminal strips TBW-5-6P and 4 shelf-adhesive rubber feet.
|
|
Relays/sensor module
|
This device is used for the surveillance and automation, for example, in remote rooms from the base station . Input for 8 analogue sensors, 10 digital sensors or a card reader/iButton reading head. Additionally, the module has 4 x 3-point relays with a maximum switching power of 10 A – 250 V AC/30 V DC. Weight: 0.6 kg, Dimensions: 145 x 30 x 90 mm. Delivery content: User manual, technical information, UTP Patch cable (1 m), 4 pins with terminal strips TBW-5-6P and 4 shelf-adhesive rubber feet.
|
|
Relays/sensor module with plug
|
Same design as the foregoing relay/sensor module however this version has sockets for cables at the rear side instead of relays like in the previous one. By means of these outputs the automation system can react to programmed events. Weight: 0.6 kg, Dimensions: 145 × 30 × 90 mm Delivery content: User manual, technical sheet, UTP Patch cable (1 m), 4 pins with terminal strips TBW-5-6P and 4 shelf-adhesive rubber feet.
|
|
GSM Module
|
The GSM module allows the user to send SMS even if the Internet connection fails. It is connected to the base unit of the PCE-IMS 1 Monitoring System.
|
|
Sensors The wide range of sensors includes, apart from temperature and humidity sensors, voltage, flooding and sensors to measure other parameters. There are different sensor types: digital and analogue sensors. They differ from each other by the type of connection and cable length. For example, in a digital input up to 6 different sensors can be connected. You will find more information regarding sensors at the top of the image in the corresponding sensor category. We are currently developing wireless sensors for the PCE-IMS 1 Monitoring System which will be available soon.
|
Sensors, analogue The maximum distance between analog sensors (except for contact sensors and level alarm systems) and the base station or any expansion module is from 30 to 50 m and will depend on the cable type. To get the maximum extension we recommend to use UTP or STP cables with RJ11 connectors. Both contact sensors and level alarm system operate even a few kilometers away. Using additional expansion modules, it is possible to add more sensors (max. 240).
|
Temperature sensor
|
Indoor temperature sensor for the sensor system with a temperature range from -40 to +100ºC. Dimensions: 60 x 18 x 18 mm, Weight: 50 g. Delivery contents: Sensor, 2 m connection cable, clamping screw, double-sided tape.
|
|
Outdoor temperature sensor
|
Outdoor temperature sensor for the automating system with a temperature range from -40 to +100ºC. 15 m connection cable fixed to the sensor Dimensions: Ø 12 x 28 mm, Weight: 450.
|
|
Air humidity sensor
|
Air humidity sensor from 20 to 95% r.H. Accuracy: 5%, Dimensions: 60 x 18 x 18 mm, Weight: 50 g. Delivery contents: Sensor, 2 m length connection cable, clamping screw, two-sided tape
|
|
Alternating voltage sensor
|
The 220 V connector is plugged into the socket which should be monitored by the PCE-IMS 1 Monitoring System, Voltage: 0 - 250 V, Weight: 100 g, Dimensions: 80 x 40 x 23 mm, connection cable: 1.8 m.
|
|
Direct voltage sensor (DC)
|
To measure and monitor direct voltage (0-100 V) Dimensions: 60 x 18 x 18 mm, Weight: 50 g. A connection cable of 1.8 m is included
|
|
Access sensor
|
Magnetic sensor to control doors and windows. PCE-IMS 1 Monitoring System can react to a sensor state, for instance, in domestic automation. Dimensions: 2 devices 60 x 18 x 18 mm, Weight: 80 g. A connection cable of 2 m and fixing material are included
|
|
Vibration sensor
|
This sensor reacts to vibrations occurred on the surface where it is mounted. This allows the PCE-IMS 1 Monitoring System to record attempted robberies or other events. Dimensions: 60 x 18 x 18 mm, Weight: 50 g. A connection cable of 2 m and fixing material are included
|
|
Ventilation sensor
|
A compact device to check air flow. It measures air flow in 4 points. If the air flow is lower at a measurement point, the sensor will be in "Warning" mode; if two or more points are lower, the sensor will be in "Alarm" mode. This sensor allows to check and test ventilation systems. Response time: 1 second. Warm-up time: 4 seconds. Fixing material is included. Dimensions: 40 x 40x 20 mm, Weight: 20 g
|
|
Smoke detector
|
The smoke detector reacts when smoke is formed. Smoke detectors can be connected in series to use only a port of the PCE-IMS 1 Monitoring System. Weight: 220 g, Dimensions: Ø 100 x 45 mm. A connection cable of 2 m and fixing material are included
|
|
Movement warning
|
The movement warning reacts to movements by means of the infrared measurement. As well as with the other sensors, this allows the PCE-IMS 1 Monitoring System to react. Dimensions: 105 x 57 x 40 mm, Weight: 120 g. Fixing material is included
|
|
Flooding sensor
|
The metallic bars of this sensor are water detectors, so it will react to the direct contact with water. This allows the PCE-IMS 1 Monitoring System to create an alarm. Dimensions: 60 x 18 x 18 mm, Weight: 60 g. A connection cable of 2 m and fixing material are included
|
|
Water sensor
|
This sensor has a detection cable which reacts when it is in direct contact with water so the PCE-IMS 1 Monitoring System can access to difficult access areas. Response time: 7-12 seconds. Cable length: 1-100 m. Dimensions: 60 x 18 x 18 mm, Weight: 20 g. A connection cable of 2 m and fixing material are included
|
|
Digital sensors, (combined sensors) The maximum digital cable length is 300 m and a 2-thread UTP cable is used. Due to the cable resistance and electromagnetic interferences, a cable with a maximum length of 50-100 m is recommended. These sensors have RJ-11 connector which can be plugged into any module digital input of the PCE-IMS 1 Monitoring System or to any other digital sensor outputs. Sensors are automatically installed and detected. Digital sensors are installed in series. Up to 6 digital sensors can be connected to a digital input of any module of the PCE-IMS 1 Monitoring System in the order you require.
|
Humidity and temperature sensor
|
This sensor measures indoor temperature as well as air humidity, Temperature range: 20ºC to +60ºC Relative humidity: 20 - 95%, Accuracy: 5 %. Dimensions: 60 x 18 x 18 mm, Weight: 50 g. A connection cable of 2 m and fixing material included
|
|
Temperature sensor and smoke detector
|
This sensor measures, in combination with the PCE-IMS 1 Monitoring System, indoor temperature as well as reacts to smoke. Temperature range: 20ºC to +60ºC Dimensions: Ø 100 x 45 mm, Weight: 220 g. A connection cable of 2 m and fixing material are included
|
|
Movement warning and temperature sensor
|
The movement warning measures indoor temperature and reacts to movements by means of the infrared measurement. Temperature range: 20ºC to +60ºC Dimensions: 105 x 57 x 40 mm, Weight: 125 g. A connection cable of 2 m and fixing material are included
|
|
|
|
Here you will find all the measuring instruments available at PCE Instruments.
|
Contact: PCE Instruments UK Limited
Unit 11 Southpoint Business Park
Ensign Way, Southampton
United Kingdom, SO31 4RF
Phone: +44(0) 23 809 870 30
Fax: +44(0) 23 809 870 39
|
Contact: PCE Americas Inc.
1201 Jupiter Park Drive, Suite 8
Jupiter 33458 FL
USA
Phone: +1-410-387-7703
Fax: +1-410-387-7714
|