Home   Data protection Gen. Terms Verifications Service Calibrations Contact Details
 

     

  Laboratory Equipment Measuring Instruments Control Systems Security Equipment Scales and Balances



Information:

- Contact us
- Guarantee
- Calibration
- Legal advice

Other instruments:

- Control systems

- Measures

- Scales
 



Air flow meter

Accurate
scales

Anemometers

Multimeters

Force 
Gauges
 

Handheld
Tachometers

Coating
thickness
meters

Data loggers

Thermo
Hygrometers
Balanza de bolsillo HC-100AS
Crane
scales

Cup vane
anemometer

Thermometers 

Current detector 

Thermal
cameras

Distance meter
Balanza contadora
Humidity content
Scales

Earth meters

Kitchen
scales

Electronic
stethoscope

Laboratory
Scales

Gas analyser

Laboratory
scales             

Gas detector for refrigerants  

Multifunction
scales

Humidity
indicators

Packaging Scale

Humidity indicator
Balanza de precisión
Pallet balances

Infrared
thermometers

Pallet truck
scales

Insulation meter
Balanza de suelo
Paper Scale



Floor scales


Platform scales

Tester for fuel 

Pocket
scales

Hanging
Scales
Báscula pesa-ejes para coches
Postal scales

Oscilloscope 

Scale for
analysis

Microscopes

Scales for
transit

Microscopes
USB
 

Tabletop
scales

Noise meters

Tabletop Scale

Power
analyzer
 

Air flow
transducers
Caudalímetro para líquidos
Power and
harmonics
analyser

Digital
indicators

Radiation
analysers

Display
systems

Radio frequency
meter

Logic
modules

Rotation
meter

Signal
converters

Videoscopes 

Temperature
transducers
Videoscopio
Voltmeter

Temperature sensors

Weather
stations

Vibration
transducers

Radio Interface / Radio Modem E805U-D
For wireless connection of RS-232 and RS-485 interfaces

The E805U-D provides a wireless connection between serial RS-232 or RS-485 interfaces. It is a cost-effective wireless alternative for connections of SPS, data loggers and computers or other devices. The E805U-D was developed for the uncomplicated and easy application. The radio modem is compact and has a radio module, power supply and serial interfaces integrated in a robust industrial casing. The radio transmission takes place via a royalty-free 869 MHz radio frequency with a performance of 500 mW and a range of up to 5 km. The installation occurs easy and reliable on a top-hat rail according to German standard DIN. If there are any questions about this Radio Interface / Radio Modem E805U-D have a look at the technical specification below or call: UK customers +44(0) 23 809 870 30 / US customers +1-410-387-7703. Our technicians and engineers will gladly advise you in all data loggers and all products in the field of measuring instruments, regulation and control and scales.

- Wireless connection between RS-232 and
  RS-485 interfaces
- Cost-efficient alternative for wireless connection
  of SPS, data loggers, computers and other
  devices
- Royalty-free 869 MHz frequency range
- Up to 5 km reach
- Transparent transmission mode
- Flexible repeater function

Radio Interface / Radio Modem E805U-D for wireless connection of RS-232 and RS-485 interfaces.

Presentation of radio transmission with 2 PCE-E805U-D in principle.

Presentation of radio transmission with 2 PCE-E805U-D in principle.

Technical Specifications

Serial interface

Standard baud rate: 1,200 until 115,200 baud RS-232 and RS-485 interfaces are internal connected with the same serial port. The serial interfaces have an asynchronous NRZ format. Characters with 7 or 8 bits with different parity and with 1 or 2 stopbits will be supported.
- RS-232: full duplex as a DCE device with
  RTS/CTS hardware Handshaking. Connection
  via 9 contacts SUB-D-socket.
- RS-485: half-duplex for Twisted Pair Mulitdrop
  Networks.
Input and output buffer: 2 Kbyte

Transmitter / Receiver

Separated channel, synthesized transmitter / receiver
Frequency: 869.4 MHz, 250KHz channel, 500 mW, expected reach in visual contact, with aerial with unit reinforcement 5 km (19.2 baud), 10 % 
relative cut-in time.
Frequency: 869.4 MHz, 250 KHz channel, 500 mW, expected reach in visual connection, with aerial with unit reinforcement 1 km (19.2 baud), 100 % relative cut-in time.
- RSSI -60 until -120 dBm
- RF data transmission rate: 19,200, 38,400,
  76,800 baud
The reach can be expanded:
- up to 5 interconnected repeater in regulated
  mode
- unlimited number of repeaters in transparent
  mode
Corresponds to standard EN 300 220
Aerial connection is SEMA coaxial

Data transmission

Transparent mode: data will be transmitted with a system and group address. The data 
transmission starts, when serial data will be received, whereas the minimum data volume is 530 byte. All modules with a correct system address that receive data packages will put out the data. Error checking is optional.
Controlled mode: data will be transmitted in packages with a system, source and target address with up to 5 interconnected repeater addresses and a 16 bit CRC error checking. Will the package be received with correct error checking only the target device will put out the data and will send back a ACK report (confirmation). If the source module does not receive an ACK report it will repeat transmission up to 4 times. DCD provides state of communication.
More: an automatic connection mode and a mode for selection control are available. CTS/RTS flow 
control will be provided based on availability of input buffer.

Configuration and diagnosis

Configuration via free of charge Windows software or Hayes AT commands. The diagnosis of radio 
noise emissions, signal strength and bit error rate are included. The value of radio signal strength is online for the main device available.

Power supply

10 – 30VDC / 12 – 24 VAC
normal power consumption:
12VDC / 70 mA or 24 VDC / 50 mA
power consumption during transmission:
12VDC / 350 mA; 24 VDC / 250 mA
power consumption sleep mode
12 VDC / 20 mA; 24 VDC / 15 mA

Indicators

LED indicators for processor OK, radio TX and RX, serial TX and RX (interfaces OK).

Connection

Removable terminal strap for easy installation of cable cross sections of up to 2.5 mm2.

Operation temperature

-40 °C until +60 °C, 0 – 99 % humidity

Standards

EMC according to ETS 300 683

Casing

Industrial stable aluminium casing

Installation

easy installation on top-hat rail

Delivery content

 

1x Radio Interface E805U-D (2 pcs. E805U-D are needed), software, user’s manual

Equipment

 

869 MHz aerial with 5 m cable and fixing

further information about the Radio Interface / Radio Modem E805U-D. return to homepage.
Here you will find an overview of all the measuring instruments available at PCE Instruments.

Contact:
PCE Instruments UK Limited
Unit 11 Southpoint Business Park
Ensign Way, Southampton
United Kingdom, SO31 4RF
Phone: +44(0) 23 809 870 30
Fax: +44(0) 23 809 870 39

Contact:
PCE Americas Inc.
1201 Jupiter Park Drive, Suite 8
Jupiter 33458 FL
USA
Phone: +1-410-387-7703
Fax: +1-410-387-7714

 

Below you will find an overview of the different product groups of measuring instruments

 Absolute Humidity Meters
 Accelerometers
 Alert Meters
 Air velocity meters
 Analyzers (Colour)
 Analyzers (Gas)
 Analyzers (Lan)
 Analyzers (Noise)
 Analyzers (Oxygen)
 Analyzers (Ozono)
 Anemometers
 Barometers
 Borescopes

Cable detectors (electrical)
Calibrators
Cameras (Infrared Thermal Imaging)
Capacitance Meters
Coating Thickness Meters
Chlorine Meters
Clamp Meters
Climate Meters
Colour Meters
Conductivity Meters
Contact Thermometers
Current detectors

Data Loggers
Differential Pressure Meters
Digital Multimeters
Densimeters
Detectors (Humidity, Radiation, Voltage)
Dose Meters (Noise)

 Earth meters
 Endoscopes
 Environmental Meters

 Fiberscopes
 Flow Meters Air
 Flow Meters Gas
 Force Gauges (digital)
 Frequency Meters

 Gas detectors
 Geiger Counter

 Handheld Tachometers
 Hardness Meters
 Humidity Testers
 (Building material)
 
Hygrometers

Indicator Sound Level
Indicators (Humidity)
Instruments (Environmental)

Impedance bridges
Infrared Thermometers
Isolation Meters

Lan Network Testers
Laser Distance Meters
Laser level
Laser meters
Laser thermometers
LCR Meters
Length Meters
Light Meters
Lux Meters

 Magnetometers
 Manometers
 Material Thickness meters

 Measurement Devices
 (Force)
 Measuring Meters
 (Distance)
 Measuring Wheels
 Meters (Distance)
 Meters (Ozone) 
 Meters (Gas) 
 Meters (Gloss)
 Meters (pH)
 Meters (Power)
 Meters (Pressure)  
 Meters (Radiation)
 Meters (Temperature)  
 Micrometers
 Microscopes
 Modular signal 
 Converters
 Moisture Indicator
 Multimeters
 Multi-Parameter    
 photometers

Noise Meters

 Odometers
 Ohm Meters
 Oscilloscopes
 Oxygen Meters
 Paper Moisture Meters
 Penetrometers
 Pitot tube air flow
 meters
 Pocket pH-meters
 Power Analyzers
 Pressure Gauges
 Pyrometers
 Quality Meters (Air)
 Radiation Counters
 Radioactivity meters
 Reader (Temperature)

 Recoders Data
 Redox Meters
 Refractometers

 Relat. Humidity meters
 Rotation meters
 Roughness tester
 Salt Meters
 Sensor (Temperature)
 Signal Level Analyzers
 Single-parameter  
 Photometers
 Sound Level Meters
 Systems for 
 Environmental
 Stethoscopes 
 (electronic)
 Stroboscopes
 Surface Thickness 
 meters

Tachometers
Telescope Meters
Thermo-anemometers
Thermo-Hygrometers
Temperature Probes
Testers (Air)
Tester (Conductivity) Tester (Earth)
Tester (Electric)
Tester (Insulation)  Tester (Noise)
Tester (pH)
Tester Resistance Tester (Sound)
Tester (Temperature)
Thermal stress
Thermal Imaging Cameras
Thermometers
Thermocouples
Thickness Meters
Turdibity Meters

Ultrasonic Flow Meters

VDE tester
Vibration Meters
Video endoscopes
Voltage meters