Home   Data protection Gen. Terms Verifications Service Calibrations Contact Details
 

     

  Laboratory Equipment Measuring Instruments Control Systems Security Equipment Scales and Balances



Information:

- Contact us
- Guarantee
- Calibration
- Legal advice

Other instruments:

- Control systems

- Measures

- Scales
 



Air flow meter

Accurate
scales

Anemometers

Multimeters

Force 
Gauges
 

Handheld
Tachometers

Coating
thickness
meters

Data loggers

Thermo
Hygrometers
Balanza de bolsillo HC-100AS
Crane
scales

Cup vane
anemometer

Thermometers 

Current detector 

Thermal
cameras

Distance meter
Balanza contadora
Humidity content
Scales

Earth meters

Kitchen
scales

Electronic
stethoscope

Laboratory
Scales

Gas analyser

Laboratory
scales             

Gas detector for refrigerants  

Multifunction
scales

Humidity
indicators

Packaging Scale

Humidity indicator
Balanza de precisión
Pallet balances

Infrared
thermometers

Pallet truck
scales

Insulation meter
Balanza de suelo
Paper Scale



Floor scales


Platform scales

Tester for fuel 

Pocket
scales

Hanging
Scales
Báscula pesa-ejes para coches
Postal scales

Oscilloscope 

Scale for
analysis

Microscopes

Scales for
transit

Microscopes
USB
 

Tabletop
scales

Noise meters

Tabletop Scale

Power
analyzer
 

Air flow
transducers
Caudalímetro para líquidos
Power and
harmonics
analyser

Digital
indicators

Radiation
analysers

Display
systems

Radio frequency
meter

Logic
modules

Rotation
meter

Signal
converters

Videoscopes 

Temperature
transducers
Videoscopio
Voltmeter

Temperature sensors

Weather
stations

Vibration
transducers

Temperature Data Logger Hobo U12-006
 4 channels, external inputs, USB port

The handy temperature data logger Hobo U12-006 measures temperature values with 4 external channels. The inputs of the temperature data logger Hobo U12-006 are ideal for temperature sensors and cables, AC current, 0 ... 2.5 V DC and 4 ... 20 mA. The temperature data logger Hobo U12-006 works completely independently, this means that it needs no external power. The temperature data logger Hobo U12-006 offers additional protocol events; it protocols the activation key, the PC connection and the battery status. Thanks to its data memory EEPROM, the values are stored even if the battery fails. The temperature data logger Hobo U12-006 is programmed through the optional software, and it is also through this software that we read the measured values. The optional software is needed to activate and program the data logger.

User manual for the Temperature Data Logger Hobo U12-006.  EC certificate for the Temperature Data Logger Hobo U12-006.  Video for the Temperature Data Logger Hobo U12-006. Temperature Data Logger Hobo U12-006: Software Technical specifications for the Temperature Data Logger Hobo U12-006.  Information for the Temperature Data Logger Hobo U12-006.

- Memory: The unit can record a total of 43,000 readings (using 4 channels the values are divided into 10,750 measurement values per channel)

- Measurement rate: adjustable from 1 second to 18 hours,  measuring time up to 1 year

- External sensors for temperature and humidity or temperature and electrical signals

- No need of calibration

-  Start time and date can be programmed

- EEPROM data memory: you do not lose data when the battery voltage fails.

- Blinking LED indicates the function

Temperature Data Logger Hobo U12-006 with 4 channels, external inputs, USB port.

 Temperature Data Logger Hobo U12-006

Technical specifications

Memory

43,000 values

Data transfer

USB (complete downlad in 30 seconds)

Measurement rate

from 1 second up to 18 hours

Battery

replaceable lithium battery CR-2032

(one year of continuous working)

Environmental conditions

-20 ... +70 °C

5...95% R.H. (non condensed)

Dimensions

58 x 74 x 22 mm

Weight

46 g

Delivery content

1 x temperature data logger Hobo U12-006 (battery included), 1 x user´s manual

Optional components

Easy set up

Selection of all parameters, including: the measurement channels that are activated. Measurement range. Immediate or delayed start, or start externally activated (Trigger button). Checking of the battery capacity

 

Real time monitoring

Numerical representation in real time on the computer. Data storage free of interruptions during transmission to the computer and during the verification of the state.

Temperature Data Logger Hobo U12-006 software.

Temperature sensor

Sensor cable with a length of 180 cm, the sensor is suitable for measurements of gases and water. However, it is not ideal for continuous use in the water. The continuous use in water below 30ºC should not exceed the maximum time of 3 months  and up to 1 month with temperatures above 30 ° C.

Range

-40 ... +100 °C (in air)

Accuracy

 from ±0.5 °C to 20 °C

Resolution

from 0.4 °C to 20 °C

Time of stabilisation in air

approx. 4.5 min (is static air)

Time of stabiisation in water

approx. 1 min (in water movement)

4...20 mA cable

Range

0 ... 20 mA

Accuracy

±0.1 mA ±1 % of measurement value

Resolution

0.4 % of final value

Length

45 cm with open ends

2.5 V cable

180 cm cable with open ends for direct connection to the temperature data logger U12-006, that is, for inputs 0 ... 2.5 V DC

10 V cable

180 cm cable with open ends for direct connection with the temperature data logger U12-006. In case you needed to have a signal from 0...10V, this is reduced to 2.5V due to integrated voltage dividor. It is used in many different industry aplications.

Current sensors (note: not approved by EC) can be obtained on request for 0 ... 20 A, 0 ... 50 A, 0 ... 100 A, 0 ... 200 A and 0 ... 600 A. The accuracy is ± 2% of final value. Input signal: AC, 50 or 60 Hz

Technical specifications for the Temperature Data Logger Hobo U12-006. return to homepage
Here you will find an overview of all the measuring instruments available at PCE Instruments.

Contact:
PCE Instruments UK Limited
Unit 11 Southpoint Business Park
Ensign Way, Southampton
United Kingdom, SO31 4RF
Phone: +44(0) 23 809 870 30
Fax: +44(0) 23 809 870 39

Contact:
PCE Americas Inc.
1201 Jupiter Park Drive, Suite 8
Jupiter 33458 FL
USA
Phone: +1-410-387-7703
Fax: +1-410-387-7714

 

Below you will find an overview of the different product groups of measuring instruments

 Absolute Humidity Meters
 Accelerometers
 Alert Meters
 Air velocity meters
 Analyzers (Colour)
 Analyzers (Gas)
 Analyzers (Lan)
 Analyzers (Noise)
 Analyzers (Oxygen)
 Analyzers (Ozono)
 Anemometers
 Barometers
 Borescopes

Cable detectors (electrical)
Calibrators
Cameras (Infrared Thermal Imaging)
Capacitance Meters
Coating Thickness Meters
Chlorine Meters
Clamp Meters
Climate Meters
Colour Meters
Conductivity Meters
Contact Thermometers
Current detectors

Data Loggers
Differential Pressure Meters
Digital Multimeters
Densimeters
Detectors (Humidity, Radiation, Voltage)
Dose Meters (Noise)

 Earth meters
 Endoscopes
 Environmental Meters

 Fiberscopes
 Flow Meters Air
 Flow Meters Gas
 Force Gauges (digital)
 Frequency Meters

 Gas detectors
 Geiger Counter

 Handheld Tachometers
 Hardness Meters
 Humidity Testers
 (Building material)
 
Hygrometers

Indicator Sound Level
Indicators (Humidity)
Instruments (Environmental)

Impedance bridges
Infrared Thermometers
Isolation Meters

Lan Network Testers
Laser Distance Meters
Laser level
Laser meters
Laser thermometers
LCR Meters
Length Meters
Light Meters
Lux Meters

 Magnetometers
 Manometers
 Material Thickness meters

 Measurement Devices
 (Force)
 Measuring Meters
 (Distance)
 Measuring Wheels
 Meters (Distance)
 Meters (Ozone) 
 Meters (Gas) 
 Meters (Gloss)
 Meters (pH)
 Meters (Power)
 Meters (Pressure)  
 Meters (Radiation)
 Meters (Temperature)  
 Micrometers
 Microscopes
 Modular signal 
 Converters
 Moisture Indicator
 Multimeters
 Multi-Parameter    
 photometers

Noise Meters

 Odometers
 Ohm Meters
 Oscilloscopes
 Oxygen Meters
 Paper Moisture Meters
 Penetrometers
 Pitot tube air flow
 meters
 Pocket pH-meters
 Power Analyzers
 Pressure Gauges
 Pyrometers
 Quality Meters (Air)
 Radiation Counters
 Radioactivity meters
 Reader (Temperature)

 Recoders Data
 Redox Meters
 Refractometers

 Relat. Humidity meters
 Rotation meters
 Roughness tester
 Salt Meters
 Sensor (Temperature)
 Signal Level Analyzers
 Single-parameter  
 Photometers
 Sound Level Meters
 Systems for 
 Environmental
 Stethoscopes 
 (electronic)
 Stroboscopes
 Surface Thickness 
 meters

Tachometers
Telescope Meters
Thermo-anemometers
Thermo-Hygrometers
Temperature Probes
Testers (Air)
Tester (Conductivity) Tester (Earth)
Tester (Electric)
Tester (Insulation)  Tester (Noise)
Tester (pH)
Tester Resistance Tester (Sound)
Tester (Temperature)
Thermal stress
Thermal Imaging Cameras
Thermometers
Thermocouples
Thickness Meters
Turdibity Meters

Ultrasonic Flow Meters

VDE tester
Vibration Meters
Video endoscopes
Voltage meters