Water in Oil Meter PCE-WIO 1 Water in
oil meter to determine the absolute moisture content of silicone-, bio-, ester- and mineral oil / moisture content in cc / calibration of send in oil (2 liters)
|
The water in oil meter PCE-WIO 1 is suitable for measuring the absolute moisture content in mineral and ester oils online. The continuous monitoring of the absolute moisture content via the sensor PCE-WIO 1 has several advantages over the random sampling of determination of water content via chemical processes. For instance, the fast recognition of water ingress caused by leakage. Thus a considerable increase of security and an avoidance of consequential damage by water in the installations will be reached. This means that repair costs and system downtimes will be reduced considerably. Oil-drying systems can be moisture-dependent controlled with the water in oil meter PCE-WIO 1. Thus energy and analysis costs are decreasing towards systems with online measuring. The continuous measuring of water content in hydraulic systems is an effective quality measure. The risk to not recognize an increase of water content between random sampling will be eliminated. Firstly the oil sent in by the customer for calibration (2 liters) will be examined regarding its water content. Afterwards the oil will undergo a drying process. Through successively adding a defined water amount again in a closed oil circuit, a calibration curve can be determined. For determination of dependence of measuring values of temperature the calibration of various oil temperatures will be executed. If you require any assistance with the water in oil meter, do not hesitate to contact us on: UK customers +44(0) 23 809 870 30 / US customers +1-410-387-7703. An overview of all absolute moisture meters can be found here: Absolute moisture meters Our technicians and engineers will gladly give you advice on this water in oil meter and all other products in the field of measuring instruments, regulation and control and scales.
|
|
|
- Operating pressure up to 30 MPa - Temperature compensation - Sensor IP65 - Quick response times - Cost-effective - Sintered-metal protection factors - Easy installation
|
- 2-button operation - Calibration with certified test medium - Switch output - RS232 interface - Compatibility with the standard media - No extra power supply necessary for sensors
|
Technical Specification Sensor
|
Measurement range water content
|
10 … 10,000 ppm in oil
|
Measurement range temperature
|
-20 … 60 °C
|
Measuring accuracy
|
depends on calibration data, mistakes < 10% of measured value
|
Operating pressure
|
vacuum up to 30 MPa
|
Operating temperature
|
-20 … 60 °C
|
Compatibility with media
|
different with aggressive substances has to be cleared up
|
Power supply
|
18 … 28 V DC approx. 30 … 70 mA
|
Output
|
RS 232 data I/O for computer interface connection current output 4-20 mA switch output (optional) 24 V DC, max 100 mA
|
Connectors
|
circular channel, 7 contacts, type Binder 723
|
Protection class
|
IP 65
|
Rehearse connection thread
|
5/8 – 18 UNF, SW 22
|
Installation depth
|
50 mm
|
Casing height
|
115 mm
|
Casing diameter
|
60 mm
|
Total length
|
176 mm
|
Technical Specification Display
|
Display
|
two line LCD display with 16 symbols each
|
Sensor connection
|
for humidity sensor
|
Interface
|
USB 2.0
|
Software
|
capable to update via USB interface
|
Storage capacity
|
12,000 measuring values
|
Operating temperature
|
-20 … 40 °C
|
Power supply
|
4 x NiMh-accumulator AA
|
Casing
|
die-cast aluminium
|
Dimensions
|
100 mm x 200 mm x 24.4 mm
|
Protection class casing
|
IP 66
|
Protection class plug connectors
|
IP 67
|
Installation
|
handheld device for operation in any position
|
The sensor of the water-in-oil meter should be used in a place where moisture content of oil is most significant. For instance, if a cooler-breakdown as a source is to be feared, a measurement point right behind cooler discharge in the pipeline should be chosen. If the quality of oil brought into the system should be monitored, a place in the suction tube of the pump is to be chosen. The installation takes place via tapped hole that is arranged in the way that the sensor element is constantly passed by the monitored oil.
|
|
|
The sensor head of the water-in-oil PCE-WIO consists of stainless steel with 5 /8-18 UNF screw-in thread. The probe element for temperature and moisture is placed at the sensor head. The sensor has to be brought in the oil flow for measuring. The elements are protected by a sleeve against strong flow. The sensor is dimensioned for medium pressures up to 300 MPa. The electric connection takes place via a 7-polar round plug connector of the type of binder-723.
|
Delivery Content
|
1x Water-in-Oil Meter PCE-WIO 1, 1x moisture sensor, 1x carrying strap with cable holder, 1x sensor cable (2m), 4x NiMh accumulator AA, 1x battery charger for AA cells, 1x USB cable (1.5), 1 x CD with software and documentation, 1 x user’s manual
|
|
|
Here you will find an overview of all the measuring instruments available at PCE Instruments |
Contact: PCE Instruments UK Limited
Unit 11 Southpoint Business Park
Ensign Way, Southampton
United Kingdom, SO31 4RF
Phone: +44(0) 23 809 870 30
Fax: +44(0) 23 809 870 39
|
Contact: PCE Americas Inc.
1201 Jupiter Park Drive, Suite 8
Jupiter 33458 FL
USA
Phone: +1-410-387-7703
Fax: +1-410-387-7714
|