UMU 100 Universal transducer Universal transducer for Pt100 sensors / connection for 2, 3 and 4-thread conductors as well as for thermo elements / additionally for current and voltage inputs
|
The UMU 100 universal transducer is the ideal device for Pt100 sensors as well as for thermo elements (type K, J, etc). The UMU 100 universal transducer can avoid damages in both machines and production plants. The UMU 100 universal transducer integrates current and voltage output signals. The UMU 100 universal transducer can optionally have a relay to check for instance a visual alarm when it exceeds the alarm limit. Thanks to the galvanic insulation, power supply does not affect the measured signal, so the UMU 100 universal transducer is a safe and accurate measurement device for your company. Here you can find the universal transducer that best suits your needs.
|
View or print user manual of the UMU 100 universal transducer
|
- For Pt100 sensors and thermo elements
- Error display
- Universal power supply
- Galvanic insulation (inputs and outputs)
|
- 2 optional alarm relays
- Voltage and current input
- Voltage and current output
- It can be connected to a display
|
Technical specifications |
Input |
Measurement range
|
Accuracy |
Pt100 |
-200 °C ... 850 °C |
±0.2 °C |
Linear resistance |
0 Ω ... 10 kΩ |
±0.1 Ω |
Potentiometer |
10 Ω ... 100 kΩ |
--- |
Thermo element (depending on the thermo element type) |
- 200 °C ... 2300 °C |
±2 °C |
Current (free programming) |
0 mA ... 20 mA
4 mA ... 20 mA |
±4 µA |
Voltage (free porgraming) |
0 V ... 1 V DC
0.2 V ... 1 V DC
0 V ... 5 V
1 V ... 5 V
0 V ... 10 V
2 V ... 10 V
|
±0 µV
|
Output |
Range |
Load |
Current |
0 mA ... 20 mA
4 mA ... 20 mA
20 mA ... 0 mA
20 mA ... 4 mA
|
maximum
20 mA, 800 Ω, 16 V DC |
Voltage |
0 V ... 1 V DC
0.2 V ... 1 V DC
0 V ... 5 V
1 V ... 5 V
0 V ... 10 V
2 V ... 10 V
1 V ... 0 V DC
1 V ... 0.2 V DC
5 V ... 0 V
5 V ... 1 V
10 V ... 0 V
10 V ... 2 V
|
min. 500 kΩ
|
Relays (close, open, Hold) |
Maximum voltage: 250 V RMS Maximum current: 2 A AC or 1 A DC
Maximum power (AC): 500 VA |
General specifications |
Power supply |
24 V AC ... 230 V AC/50 Hz ... 60 Hz
24 V DC ... 250 V DC |
Max. absorbed power |
≤2.5 W |
Response time (0 % ... 90 %/100 % ... 0 %) |
Temperature
input: ≤1 s
Current and voltage input: ≤400 ms |
Calibration temperature |
20 °C ... 28 °C |
Max. relative humidity |
90 % r.H. |
Dimensions with front display |
109 x 23.5 x 116 mm |
Dimensions without front display |
109 x 23.5 x 104 mm |
Protection |
Case: IP 50
Terminals: IP 20 |
Weight |
175 g |
Here you can see the different connection types of the UMU 100 universal transducer
|
Delivery content
1 x UMU 100 universal transducer, 1 x user manual |
|
|
Here you will find an overview of all the measuring instruments available at PCE Instruments. |
Contact: PCE Instruments UK Limited
Unit 11 Southpoint Business Park
Ensign Way, Southampton
United Kingdom, SO31 4RF
Phone: +44(0) 23 809 870 30
Fax: +44(0) 23 809 870 39
|
Contact: PCE Americas Inc.
1201 Jupiter Park Drive, Suite 8
Jupiter 33458 FL
USA
Phone: +1-410-387-7703
Fax: +1-410-387-7714
|
This page in German in Italian in Spanish in Croatian in French in Hungarian in Turkish in Polish in Russian in Dutch in Portuguese in Portuguese
|