PCE-PCM2 Clamp Meter |
||
The PCE-PCM2 clamp meter is designed to measure both alternating and direct current up to 1500 A. The PCE-PCM2 clamp meter can also detect power by measuring voltage and current. The PCE-PCM2 clamp meter is also used to measure diode resistance, capacity, continuity and voltage. The PCE-PCM2 clamp meter additionally determines mains frequency. Through an internal sensor, the PCE-PCM2 clamp meter can detect voltage-free lines. The PCE-PCM2 clamp meter can perform measurements in cables and lines with a maximum diameter of 52 mm. The large backlit LED display ensures easy reading of measured values. The PCE-PCM2 clamp meter has a robust and rubberized enclosure which allows to use it even in adverse conditions. Here you will find an overview of all the clamp meters available at PCE Instruments. |
||
View or print user manual of the PCE-PCM2 Clamp Meter
|
||
- Measures current up to 1500 A - Measures AC/DC power - Measures voltage up to 1000 V |
- Temperature measurement through a - Displays digital bar-graph - Search of current lines |
|
Technical specifications: |
||
DC A current | ||
Measurement Range |
Resolution |
Accuracy |
400 A | 0.01 A | ±(2 % + 30 digits) |
1000 A | 0.1 A | ±(2.5 % + 30 digits) |
AC A current | ||
Measurement Range |
Resolution |
Accuracy |
400 A | 0.01 A | ±(2.5 % + 30 digits) |
1000 A | 0.1 A | ±(2.8 % + 30 digits) |
Note: The mentioned accuracy refers to AC A measurements within a range between 5 % and 100 % of the measurement range. |
||
DC A voltage | ||
Measurement Range |
Resolution |
Accuracy |
400 mV | 0.01 mA | ±(0.1 % + 9 digits) |
4 V | 0.0001 V | ±(0.1 % + 4 digits) |
40 V | 0.001 V | ±(0.1 % + 4 digits) |
400 V | 0.01 V | ±(0.1 % + 4 digits) |
1000 V | 0.1 V | ±(0.5 % + 4 digits) |
Voltage measurement (AC V, 50 ... 100 Hz) | ||
Measurement Range |
Resolution |
Accuracy |
400 mV | 0.01 mV | ± (0.8 % + 9 digits at 50/60 Hz) |
4 V | 0.0001 V | ± (1 % + 30 digits) |
40 V | 0.001 V | ± (1 % + 30 digits) |
400 V | 0.01 V | ± (1 % + 30 digits) |
750 V | 0.1 V | ± (1 % + 30 digits) |
Note: Mentioned accuracy refers to AC A measurements within a range between 5 % and 100 % of the measurement range. | ||
Power DC kW measurement (0 to 600 V, 0 to 1500 A) | ||
Measurement Range |
Resolution |
Accuracy |
900 kW | 0.1 | ± (2.8 % + 10 digits) |
Power measurement (0 to 600 V, 0 to 1500 A) | ||
Measurement Range |
Resolution |
Accuracy |
900 kW | 0.1 | ± (3 % + 10 digits) |
Note: The mentioned accuracy refers to AC A measurements within a range between 5 % and 100 % of the measurement range. | ||
Resistance measurement | ||
Measurement Range |
Resolution |
Accuracy |
400 Ω | 0.01 | ± (0.5 % + 9 digits) |
4 kΩ | 0.0001 | ± (1 % + 4 digits) |
40 kΩ | 0.001 | ± (1 % + 4 digits) |
400 kΩ | 0.01 | ± (1 % + 4 digits) |
4 MΩ | 0.0001 | ± (2 % + 10 digits) |
40 MΩ | 0.001 | ± (3 % + 10 digits) |
Capacity | ||
Measurement Range |
Resolution |
Accuracy |
400 nF | 0.01 | ± (3.5 % + 40 digits) |
4000 nF | 0.1 | ± (3.5 % + 10 digits) |
40 µF | 0.001 | ± (3.5 % + 10 digits) |
400 µF | 0.01 | ± (3.5 % + 10 digits) |
4 mF | 0.0001 | ± (5 % + 10 digits) |
20 mF | 0.001 | ± (5 % + 10 digits) |
420 mF | 0.001 | non-specified |
Frequency measurement | ||
Measurement Range |
Resolution |
Accuracy |
40 Hz | 0.001 | ± (0.3 % + 2 digits) |
400 Hz | 0.01 | |
4 kHz | 0.0001 | |
40 kHz | 0.001 | |
400 kHz | 0.01 | |
4 MHz | 0.0001 | |
40 MHz | 0.001 | |
Working cycle | ||
Measurement Range |
Resolution |
Accuracy |
10 ... 95 % | 0.1 | ± (1 % + 2 digits) (of the measurement value) |
Temperature | Resolution | Accuracy |
-100 ... 1000 ºC | 0.1 | ± (1% ... +2.5 ºC) (of the measurement value) |
General technical specification: | ||
Diameter of the conductor |
max. 52 mm |
|
Display | two lines 40.000/4.00 | |
Input impedance | 10 MΩ | |
Bandwidth AC (AC A/AC V) | 50 ... 400 Hz | |
AC Measurement | True effective value | |
Operating conditions |
5 ... 40 ºC |
|
Storage conditions | -20 ... 60 ºC max. 80 % <80 % H.r. |
|
Power supply | 9 V battery | |
Auto shut-off |
after approx. 30 minutes |
|
Dimensions |
294 x 105 x 47 mm |
|
Weight | 536 g | |
Standards | IEC 1010-1, EN 61010-1, CAT III | |
|
||
|
Delivery content: |
|
Here you will find an overview of all the measuring instruments available at PCE Instruments. |
||
Contact: |
Contact: |
Below you will find an overview of the different product groups of measuring instruments |
||||||||||||||||||||||||||
|
|
|
|