Three-phase
Harmonic Analyser PCE-GPA 62 Three-phase
harmonic analyser / power and energy meter (real time) with data logger, graphic display, interface for PC and software
|
The three-phase harmonic analyser (Graphic Power Quality Analyser) PCE-GPA 62 is used for single-phase or three-phase measurements of active, reactive and apparent power, power factor, phase angle, energy, voltage, current as well as peaks and harmonics up to 50º of the harmonic waveform. The three-phase harmonic analyser PCE-GPA 62 comes with a built-in graphic display to show network analyser values. Measured values can be both recorded and transferred to a PC for further analysis. The three-phase harmonic analyser PCE-GPA 62 is a professional handheld device for determining several parameters. Thanks to the backlit display, it is possible to get an accurate reading of measured values even in poor light conditions. Although the three-phase harmonic analyser PCE-GPA 62 comes calibrated from the manufacturer, an optional laboratory calibration and certificate (ISO standards) can be ordered separately with the device or when an annual recalibration is required. Here you will find an overview of the analysers which will suit your needs.
|
|
- Real-time test, register and measurement of voltage and current (real effective) - Measures power factor and phase angle, frequency, energy, active, reactive and apparent power (single-phase or three-phase in symmetrical networks) - Max. conductor diameter: 55 mm - Graphic display - Auto shut-off after 15 min. (this function can be disabled) - Optional ISO calibration
View or print user manual of the three-phase harmonic analyzer PCE-GPA 62
|
The graphic display shows measured values as figures.
|
The graphic display can also show measured values as a curve.
|
Soft rubber keys to make programming and adjusting easier.
|
Rotary switch for function selection of the three-phase harmonic analyser PCE-GPA 62.
|
Optical interface at the back of the three-phase harmonic analyser PCE-GPA 62.
|
Optical adapter (optical interface to USB, 2 m cable).
|
Technical specifications:
|
Measurement values Voltage measurement Voltage peaks (> 10 V) -Current measurements Current peaks (> 20 A) Active power P Apparent power S Reactive power Q PF power factor Phase angle Frequency measurement (U > 50 V) Active energy Apparent energy Active energy Harmonics in the voltage (relative) 50 - 60 Hz > 80 V AC Harmonics in the voltage (absolute) 50 - 60 Hz > 80 V AC Harmonics in the current (relative) 50 - 60 Hz > 80 V AC Harmonics in the current (absolute) 50 - 60 Hz > 80 V AC Total harmonic distortion (THD-F) 50 - 60 Hz > 80 V and > 20 A
|
Measurement ranges/Accuracy/Resolution 4.0 ... 600.0 V RMS value ± 0.5 % of the measured value ± 5 digits/0.1 V 50 Hz - 60 Hz/± 5 % ± 50 digits 4.0 ... 1500 A real 50 Hz - 60 Hz/± 5 % ± 50 digits 10 W ... 9999 kW in 5 measurement ranges ± 1 % of the value + 20 digits (>20 V and >20 A) ± 2 % of the value + 40 digits (>20 V and >20 A) 0.1 W ... 1 kW according to the measurement range 10 VA ... 9999 kVA in 5 measurement ranges ± 1 % of the value + 20 digits (>20 V and >20 A) ± 2 % of the value + 40 digits (>20 V and >20 A) 0.1 VA ... 1 kVA according to the measurement range 10 VAr ... 9999 kVAr in 5 measurements ranges ± 1 % of the value + 20 digits (>20 V and >20 A) ± 2 % of the value + 40 digits (>20 V and >20 A) 0.1 VAr ... 1 kVAr according to the measurement range 0.000 ... 1.000 ± 0.04 (>20 V and >20 A)/0.001 ± 0.1 (>20 V and >20 A)/0.001 -180 ... +180/± 1/0.1 0 ... +360/± 1/0.1 46 ... 65 Hz ±0.3 Hz/0.1 Hz 0 ... 999,999 kWh ± 1 % of the value + 20 digits 0 ... 999,999 kVAh ± 1 % of the value + 20 digits 0 ... 999,999 kVarh ± 1 % of the value + 20 digits 1 - 20 th/± 2 %/0.1 % 21 - 50 th/± 4 % of the value ± 2 %/0.1 % 1 - 20 th/± 2 %/0.1 % 21 - 50 th/± 4 % of the value ± 0.5 %/0.1 % 1 - 20 th/± 2 % / 0.1 % 21 - 50 th/± 4 % of the valuew ± 2 %/0.1 % 1 - 20 th/± 2 % of the value ± 0.4 A/0.1 A 21 - 50 th/± 4 % of the value ± 0.4 A/0.1 A 0.0 - 20 %/2 %/0.1 % 20.1 - 100 %/± 6 % of the value ± 1 %/0.1 % 100.1 - 999.9 %/± 10 % of the value ± 1 %/0.1 %
|
Max. clamp opening
|
55 mm
|
Range selection
|
auto
|
Overload indication
|
"OL'' = Overload
|
Memory
|
50,000 readings
|
Interface
|
USB
|
Software and data cable
|
included in the delivery. They can be used with Win 2000, XP, and ME
|
Display
|
graphic display, 128 x 64 LCD with backlight
|
Power supply
|
2 x 1.5 V AA batteries
|
Energy consumption
|
aprox. 10 mA
|
Dimensions
|
271 x 112 x 46 mm
|
Weight
|
650 g with batteries
|
Operating conditions
|
85 % max. R.H./-10 ... + 50 °C
|
Protection/Standards
|
CAT III 600 V/EN 61010-2-032
|
Use of the three-phase harmonic analyser PCE-GPA 62
|
|
|
|
|
Connection outline
|
Measurement of the waveform average value (RMS), THD-F and harmonics
|
Measurement of the three-phase power, power and power factor.
|
Measurement of the single-phase power
|
Software
|
The software shows data as a curve or as an analogue graphic
|
The software also shows data as columns or figures.
|
Delivery content: 1 x three-phase harmonic analyser PCE-GPA 62, 2 x isolated measuring pins with 2 m cable, 2 x batteries, 1 x carrying case, 1 x USB cable for a PC, 1 x software (in English) and user manual
|
|
Optional accessories - ISO Calibration certificate
|
|
|
|