Multifunction Meter PCE-EM 886
Sound, light, temperature, moisture, and external temperature (type K) sensors included / auto-ranging digital multimeter / Large LCD / optional infrared temperature adapter
|
This digital multifunction meter combines an environment meter with a digital multimeter with auto-ranging. The multifunction meter, which is compact and easy to use with rubber casing, offers a wide variety of functions. It encompasses many measurement parameters such as resistance, capacitance, frequency, current, voltage, temperature (internal and external K by connection type), acoustic continuity test, transistor test, noise and light measurement. It also has an auto range and the "Data-Hold" function, as well as a large backlight display. This multifunction meter is suitable for industry use, electrical workshops, services, schools, universities, and hobbyists, etc. The combination of different measurements of environmental parameters grants a comfortable use almost everywhere. Optionally, we offer an adapter for IR temperature measurement without contact in a range of -30 to +500 º C. At the following link you will find other multifunction meters.
|
|
- LCD display with backlight function
- HOLD function
- Battery status indication
- Robust rubberised housing
- Measures the level of noise, light, outside temperature via thermocouple type K, temperature and humidity
- The meter includes an automatic range selection
- You can purchase an infrared temperature adapter as a complement
|
Please note: The multifunction meter is only for indicative measurements and demonstrations. If you need precise and high reproducibility measurements, please purchase equipment that measures a single parameter. Find the right equipment here.
View or print the user manual for the PCE-EM 886 Multifunction Meter
|
Functions of the components
|
Sound Level Meter
|
Measurement range |
35...100 dB |
Resolution |
0.1 dB |
Frequency range |
30 Hz...10 kHz |
Frequency rating |
rating C |
Temporary rating |
fast |
Accuracy |
± 5 dB at 94 dB, 1kHz sine wave |
Microphone |
electric condenser microphone |
Light meter
|
Measurement range |
4000/40,000 lux (Light range of 20,000 = indicator x 10) |
Overcoming range |
"OL" (you must select a superior measuring range) |
Accuracy |
±5 % measurement value +
10 digits |
Reproducibility |
±2 % |
Temperature characteristic |
±0.1 %/°C |
Sensor |
silicon photodiode with filter |
Moisture meter
|
Measurement range |
33...99 % H.r. |
Resolution |
1 % |
Accuracy |
±3 % measurement value + 5 % H.r. |
Temperature meter
|
Measurement range |
0 ... 50 °C |
Resolution |
0.1°C |
Accuracy |
±3 % measurement value ±3 °C
|
Thermocuple Type K Connection
|
Measurement range |
-20 ... 400 ºC -20 ... 1300 ºC |
Resolution |
0.1 ºC 1 ºC |
Accuracy |
±3 % measurement value + 3 ºC |
Multimeter
|
Measurement range - Voltage DC - Voltage AC - Current DC - Current AC - Resistance - Capacity - Frequency |
400 mV/4/40/100/250 V 400 mV/4/40/100/250 V 400/4000 µA/40/400
mA/10 A 400/4000 µA/40/400 mA/10 A 400 Ω/4/40/400 Ω/4/40 MΩ 50/500
nF/5/50/100 µF 5/50/500 Hz/5/50/500 kHz/10 MHz |
Resolution - Voltage DC - Voltage AC - Current DC - Current AC - Resistance - Capacity - Frequency |
0.1/1.0/10/100 mV/1 V 0.1/1.0/10/100 mV/1 V 0.1/1/10/100 µA/10 mA 0.1/1/10/100 µA/10 mA 0.1/1/10/100 Ω/10 kΩ/1 MΩ 10
pF/0.1/1/10 nF/0.1 µF 0.001/0.01/0.1/1/10/100 Hz/1 kHz |
Precision - Voltage DC |
±1 % value ±4 digits (up to 40 V) ±1.5 % value ±4 digits (above) |
- Voltage AC |
±1.5 % value ±1.5 digits (up to 400 mV) ±1 % value ±4 digits (up to 40 V) ±1.5 % value ±4 digits (up to 100 V) ±2 % value ±4 digits (up to 250) |
- Current DC |
±1 % value ±2 digits (up to 40 mA) ±1.2 % value ±2 digits (up to 400 mA) ±2 % value ±5 digits (up to 10 A) |
- Current AC |
±1.2 % value ±2 digits (up to 40 mA) ±1.5 % value ±2 digits (up to 400 mA) ±2 % value ±5 digits (up to 10 A) |
- Resistance |
±1.5 % dvalue ±4 digits (up to 400 Ω) ±1.5 % value ±5 digits (up to 400 kΩ) ±2 % value ±2 digits (up to 4 mΩ) ±2.5 % value ±5 digits (up to 40 mΩ) |
- Capacity |
±5 % value ±20 digits (up to 50 nF) ±3 % value ±5 digits (up to 50 µF) ±4 % value ±5 digits (up to 100 µF) |
- Frequency |
±1.2 % value ±3 digits (up to 500 kHz) ±1.5 % value ±4 digits (up to 10 MHz) |
Overvoltage category |
CAT II 600 V/CAT III 300 V |
General comments
|
Display |
LCD display, 3 4/5 digits |
Overrating indicator |
"OL" |
Measurement sequence |
approx. 3 per second |
Temperature for the desired accuracy |
23 °C ± 5°C/<70 % H.r. |
Ambient conditions |
0...+40 °C/<70 % H.r. |
Storage conditions |
-10...+60 °C/<80 % H.r. |
Power supply |
1 x battery of 9 V |
Meter dimensions |
170 x 78 x 48 mm |
Weight |
335 g |
Images of applications of the PCE-EM 886 Multifunction Meter |
Temperature measurement using the infrared temperature external adapter
|
Checking the temperature of an engine with PCE-EM 886 Multifunction Meter
|
PCE-EM 886 Multifunction Meter verifying temperature measurement with K type thermocouple
|
The Multifunction Meter PCE-886 EM verifying measurement with the multimeter function
|
Delivery content 1 x PCE-EM 886 Multifunction Meter 1 x type K temperature sensor 1 x check cables 1 x 9 V battery 1 x user instructions
|
|
- Infrared temperature adapter Adapter for non-contact temperature measurement with 1 m cable. - Measuring range: -30 ... 550 ° C - Accuracy: ± 2% of measured value - Value Distance/measuring point: 8:1 - Degree of issue: fixed (0.95) - 1 mV/1 ° C
|
|
- Adapter for ampere meter clamp Adapter for indirect measurement of current up to 1000 A without an interruption of the driver
- Rank: 200/1000 DCA/ACA
- Output signal: 0 - 1V DC
- Accuracy: ± 1.5/2%
- DCA zero adjustment
- Dimensions: 190 x 64 x 33 mm
- Maximum conductor diameter: 33.5 mm
- Power supply: 9 V battery
|
|
- Speed adapter Adapter with speed sensor, 1 m cable. For optical measurement of the speed between 100 ... 20,000 rpm in two ranges.
- 0.1 mV DC/1 RPM (Rank 1)
- 0.1 mV DC/10 RPM (Rank 2)
- Dimensions: 190 x 73 x 37 mm
- Power supply: 9 V battery
|
|
- Pressure adapter.
Pressure sensor adapter, 1 m. cable. To measure absolute pressure between 3.5 ... 3500 kPa.
- Accuracy: ± 1% (up to 1700 kPa), ± 2% (up to 2400 kPa) and ± 5% (up to 3500 kPa)
- Resolution: 0.1/1 kPa
- Dimensions: 100 x 50 x 25 mm , 1/4 "sensor.
|
|
- Light adapter - Light sensor adapter and 1 m. cable
- Three measuring ranges: 0 ... 2000/0 ... 20000 to 0 ... 50000 lux
- Accuracy: ± 5%
- Resolution: 1,10,100 lux
- Dimensions: 100 x 50 x 25 mm
|
|
- Adapter for air speed
- Adapter for air speed sensor adapter for air velocity with 1 m cable
- Measuring range: 0.2 ... 30 m/s;
- Accuracy: ± 2%
- Resolution: 0.1 (m/s, km/h, knots)
- Dimensions: 100 x 50 x 25 mm
|
|
- Sound adapter Sound sensor and adapter 1m cable.
Rating A;
- Possibility of external calibration (gauge PCE-SC 41)
- Measuring range: 30 ... 130 dB (in 3 ranges)
- Accuracy: ± 1.5 dB (IEC 651 Class II)
- Dimensions: 107 x 53 x 29 mm
|
|
- EMF adapter EMF sensor and adapter cable 1 m.
- Range: 0 ... 20 microTesla/200 milliGauss
- Accuracy: ± 4%
- Resolution: 0.1 μTesla/1 milliGauss
- Bandwidth: 30 ... 300 Hz
- Dimensions: 100 x 50 x 25 mm
|
|
|
|
Here you will find all the measuring instruments available at PCE Instruments.
|
Contact: PCE Instruments UK Limited
Unit 11 Southpoint Business Park
Ensign Way, Southampton
United Kingdom, SO31 4RF
Phone: +44(0) 23 809 870 30
Fax: +44(0) 23 809 870 39
|
Contact: PCE Americas Inc.
1201 Jupiter Park Drive, Suite 8
Jupiter 33458 FL
USA
Phone: +1-410-387-7703
Fax: +1-410-387-7714
|