PCE-PA 8300 Power Analyser 3
phases, measures power and analyses harmonics and system incidents / up to
3000 A AC /
with SD memory / graphic display / various current clamps
|
The PCE-PA 8300 power and harmonics analyser
stands out due to its simple handling. The Power Analyser saves all the measured
data on a SD memory card. The PCE-PA 8300 Power Analyser can be used to measure
the capacity as well as to perform an analysis on the network. The power
anaylser PCE-PA 8300 can measure power up to 9999 MW.
For analysis on the network the PCE-8300 exactly determines the power and
network as well as harmonics up to the 50th order. All measured values are
indicated on the graphic LCD display. Thus it is an easy task for the power
analyser to detect distortions. For an exact analysis of the netwrk and its
power the measurement data can be stored on the SD memory card with any back-up
interval of your choice. Thus the Power Analyser facilitates long-term
measurements. The Power Analyser can be purchased in two different kits. It can
be either purchased with current clamps or with flexible rogowski coils. If there are any questions about this
Power Analyser PCE-PA 8300 please
have a look at the technical specification below or call:
UK customers +44(0) 23 809 870 30 / US customers
+1-410-387-7703. Our technicians and engineers will gladly advise you regarding all
power
analysers and all products in the field of measuring
instruments, regulation
and control and scales.
|
|
|
-
3-phase Power Analyser
- measures up to 3000 A AC
- power clamps or rogowski coils
- harmonics analyser
- apparent, effective and reactive power
- measures efficiency power
- power clamps of various manufacturers
|
-
SD memory
- Adjustable back-up interval
- measures up to 600 V AC
- measures delay angle and frequency
- graphic display with display of harmonics
- robust enclosure
- auto- setting of measurement range (AC V)
|
Technical specifications
of the Power Analyser PCE-PA 8300
|
Electrical
Specifications |
Voltage
measurement (AC V) |
Measurement
range |
Resolution |
Accuracy |
10
V ... 600 V (phase to neutral) |
0.1
V |
±
(0.5 % + 0.5 V) |
10
V ... 600 V (phase to phase |
0.1
V |
±
(0.5 % + 0.5 V) |
Current
measurement (AC A) Set 1 |
Measurement
range |
Resolution |
Accuracy |
20
A |
0.001
A (< 10 A)
0.01 A (≥ 10 A) |
±
(0.5 % + 0.1 A) |
200
A |
0.01
A (< 100 A)
0.1 A (≥ 100 A) |
±
(0.5 % + 0.5 A) |
1200
A |
0.1
A (< 1000 A)
1 A (≥ 1000 A) |
±
(0.5 A + 5 A) |
Current
measurement (AC A) Set 2 |
Measurement
range |
Resolution |
Accuracy |
30
A |
0.001
A (< 10 A)
0.01 A (≥ 10 A) |
±
(0.5 % + 0.1 A) |
300
A |
0.01
A (< 10 A)
0.1 A (≥ 10 A) |
±
(0.5 % + 0.5 A) |
3000
A |
0.1
A (< 1000 A)
1 A (≥ 1000 A) |
±
(0.5 A + 5 A) |
Effective
power |
Measurement
range |
Resolution |
Accuracy |
0
KW ... 9.999 KW |
0.001
KW |
±
(1 % + 0.008 KW) |
10
KW ... 99.99 KW |
0.01
KW |
±
(1 % + 0.08 KW) |
100
KW ... 999.9 KW |
0.1
KW |
±
(1 % + 0.8 KW) |
1
MW ... 9.999 MW |
0.001
MW |
±
(1 % + 0.008 MW) |
Apparent
Power |
Measurement
range |
Resolution |
Accuracy |
0
KVA ... 9.999 KVA
|
0.001
KVA
|
±
(1 % + 0.008 KVA)
|
10
KVA ... 99.99 KVA
|
0.01
KVA
|
±
(1 % + 0.08 KVA)
|
100
KVA ... 999.9 KVA
|
0.1
KVA
|
±
(1 % + 0.8 KVA)
|
1
MVA ... 9.999 MVA
|
0.001
MVA
|
±
(1 % + 0.008 MVA)
|
|
Reactive
Power |
Measurement
range |
Resolution |
Accuracy |
0
KVAR ... 9.999 KVAR |
0.001
KVAR |
± (1 %
+ 0.008 KVAR)
|
10
KVAR ... 99.99 KVAR |
0.01
KVAR |
± (1 %
+ 0.08 KVAR )
|
100
KVAR ... 999.9 KVAR |
0.1
KVAR |
± (1 %
+ 0.8 KVAR )
|
1
MVAR ... 9.999 MVAR |
0.001
MVAR
|
±
(1 % + 0.008 MVAR) |
Active
Energy |
Measurement
range |
Resolution |
Accuracy |
0
KWH ... 9.999 KWH |
0.001
KWh |
± (2 %
+ 0.008 KWh)
|
10.00
KWH ... 99.99 KWH |
0.01
KWh |
±
(2 % + 0.08 KWh) |
100.0
KWH ... 999.9 KWH |
0.01
KWh |
±
(2 % + 0.8 KWh) |
1
MWH ... 9.999 MWH |
0.001
MMh |
±
(2 % + 0.008 MWh) |
Apparent
Energy |
Measurement
range |
Resolution |
Accuracy |
0
KVARH ... 9.999 KVARH |
0.001
KVARh |
±
(2 % + 0.008KVARh) |
10.00
KVARH ... 99.99 KVARH |
0.01
KVARh |
±
(2 % + 0.08KVARh) |
100.0
KVARH ... 999.9 KVARH |
0.01
KVARh |
±
(2 % + 0.8KVARh) |
1
MVARH ... 9.999 MVARH |
0.001
MVARh |
±
(2 % + 0.008MVARh) |
Power
Factor |
Measurement
range |
Resolution |
Accuracy |
0
... 1 |
0.01 |
±
0.04 |
Delay
Angle |
Measurement
range |
Resolution |
Accuracy |
-180
° ... +180 ° |
0.1
° |
±
1 ° |
Frequency |
Measurement
range |
Resolution |
Accuracy |
45
Hz ... 65 Hz |
0.1
Hz |
±
0.1 Hz |
Harmonic
of AC Voltage at 50 / 60 Hz |
Measurement
range |
Resolution |
Accuracy |
1
... 20th order |
0.1
A
0.1 % |
±
(2 % + 0.5 A)
± (2 % + 10 Digit) |
21
... 30th order |
0.1
A
0.1 % |
±
(2 % + 0.5 A)
± (2 % + 10 Digit) |
21
... 50th order |
0.1
A
0.1 % |
not
specified |
General
Specification of the Power Analyser PCE-PA 8300 |
Display |
3.7
" point-matrix LCD (320 * 240 pixel) with LED background lights |
Safety
standards |
IEC1010CAT
III 600V |
Input
resistance AC V |
10
MOhm |
Operating
frequency of current clamp |
40
Hz ... 1 kHz |
Tested
operating frequency of current clamp |
45
Hz ... 65 Hz |
Overload
protection |
AC
V
AC A |
720 V RMS
1300 A with current clamp |
Data
Storage |
SD
memory card |
Recording
interval |
1
second |
Data logging
function |
logging
with real-time speed on SD memory card |
Filing
interval |
2
... 7200 seconds |
Data
output (only for live display on computer) |
per
USB or RS232, depending on connection cable |
Operating
temperature |
0
°C ... +50 °C |
Surrounding
humidity |
<
80 % RH
8 x 1,5 V AA batteries |
Voltage
supply |
9
V adapter |
Current
drain |
measurement
device: 300 mA DC
current clamp: 34 mA DC |
Maximum
wire diameter |
50
mm |
Weight |
measurement
device: 948 g (incl. battery)
current clamp: 467 g (incl. cable) |
Dimensions |
device:
225 x 125 x 64 mm
current clamp: 210 x 64 x 33 mm
clamp jaw: 86 mm (exterior) |
|
Set
1 PCE-PA 8300:
PCE-PA 8300 + PCE-PA C1 (1200 A)
-
measurement range: 20 A / 200 A / 1200 A
-
max. wire diameter: 50 mm
-
length of connection wire: 4 mm
-
frequency range: 45 Hz ... 1 KHz
-
weight: 490 g |
|
Set
2 PCE-PA 8300:
PCE-PA 8300 + PCE-PA C2 (3000 A)
-
measurement range: 30 A / 300 A / 3000 A
-
current wire input: 170 mm diameter
-
length of measurement coil: 600 mm
-
length of connecting wire: 3.4 mm
-
frequency range: 45 ... 400 Hz
-
weight: 410 g |
Caution
while using the power analyser PCE-PA 830 / Safety measures:
- Do not operate with the power analyser, the clamps or the cables, if they
show visible
damages.
- Be especially cautious while measuring on blanc wires and bus bars.
- In order to prevent any damages, perform measurements only within the ranges
that are
specified (avoid measurements close to the specified limits. Always
consider all safety measures)
- Do not use the device under extreme temperatures, in direct sunlight,
under extreme humidity
or exposed to water. - Avoid exposing the device to extreme shocks and always handle it with care. - Before turning on the device, allow it to
acclimatize to the environment it will be used in. This is particularly important when the device is taken from cold environments to
warmer ones, and vice
versa. - This device should only be repaired by qualified technicians of
PCE-instruments. - Do not place the device with its display faced down on a surface to avoid damaging the keypad. - Use the Power Analyser inside buildings. If it must be used
outside, then use only under dry
conditions. - Do not expose the device to direct sunlight, high temperatures, high humidity or condensation
when it is in use. - This device is not protected against exposure to dust or exposure to water. -
Do not expose this device in corrosives areas or to explosive gases. - Never use the Power Analyser with wet hands. - Always wear a safety suit when handling the power
analyser. - Before connecting the test cables or clamps, always disconnect the device first. - To avoid damage or a short circuit, leave the object being measured without a current before connecting the Power Analyser or the clamps. - The inputs are not
separated from each other. - Remove all lines being measured that are no being used by the installation. - First connect the test cable the the Power Analyser and then to the object being measured. - Put down the test cables
carefully when you are not using them. |
Delivery
Contents of the Power Analyser PCE-PA 8300 1 x PCE-PA 8300 power
analyser, 3 x amp clamps - depending on the ordered set,
4 x insolated alligator clips, 4 x safety test lines, 6 x 1.5 V AA batteries,
1 x 9 V mains adapter, 1 x carrying case, 1 x 2 GB SD memory card, 1 x
instruction manual
|
|
|