Precision Airflow Sensor SS
20.650
Precision airflow sensor to measure air
velocity at temperatures up to +350 °C /
maintenance-free / robust enclosure /
LED status indicator / analogue and digital output
|
This
precision airflow sensor provides an accurate air velocity measurement even at
higher temperatures. Due to a mechanically robust design by only using
high-quality material, the precision airflow sensor provides even under extreme
conditions precise and repeatable measurement results. Within the temperature
range of 0 °C ... +350 °C the precision airflow sensor is able to measure air
velocities between 0 .... +60 m/s depending on the model. The sensor head of the
precision airflow sensor resigns of movable parts and consists of
temperature-resistant ceramic, which makes it maintenance-free and allows
providing reliable data even after several years. Due to the thermal measuring
principle an additional measurement and calculation of pressure and temperature
to determine the standard volume flow becomes dispensable at the precision
airflow sensor. The internally established temperature of the precision airflow
sensor can be still emitted as a separate temperature signal if demanded so.
Flexible montage lengths up to 1000 mm expand the application ranges of the
precision airflow sensor significantly. The precision airflow sensor therefore
is especially designed for controlling burning processes, monitoring drying
procedures or to monitor air compressors. In case that you should have more questions regarding the
precision airflow sensor SS 20.650, please read the following technical data, use our
contact form or call us: UK customers +44(0) 23 809 870 30 / US customers +1-410-387-7703.
Our technicians and engineers will gladly advise you regarding the airflow
sensors or all other products in the field of Control
Systems, Laboratory
Equipment, Measuring
Instruments or Scales
and Balances of PCE
Instruments Ltd.
|
|
|
-
Operating indicator by Duo-LED
- Fieldbus and profibus option
- Measuring range up to 60 m/s
- For temperatures up to +350 °C
|
-
Low weight
- Ceramic sensor head
- Up to max. 16 bar operating pressure
- Special edition with ±1 % accuracy
|
Technical specifications
|
Measurement
|
standard
velocity wN in relation to standard conditions of +20 °C and
1013.25 hPa
|
Measuring
medium
|
Air
and nitric, further gasses on demand
|
Lower
limit of measuring range
|
0.2
m/s
|
Measurement
accuracy
Standard
|
High
Precision (optional)
|
±
(3 % fr. val. + 0.4 % fr. measuring range)1
± (1 % fr. val. + 0.4 % fr. measuring range)1
|
Repeatability
wN
|
±0.5
% fr. value
|
Response
time t90
|
3
sec. (skip from 0 to 5 m/s)
|
Temperature
gradient
|
8
K/min at wN = 5 m/s
|
Pressure
dependence
|
Independent
of pressure of the medium
|
Measuring
range temperature
|
0
... +200 °C / +350 °C
|
Measuring
accuracy temperature
|
±1
% fr. val. (at least 1 K)
|
Operation
temperature
|
-
Measuring sensor
|
0
... +200 °C / +350 °C (depending on version)
|
-
Electronics
|
-20
... +70 °C
|
Operation
pressure
|
standard
edition: 700 ... 1300 hPa
pressure-proof high temp. edition: 0 ... 16 bar
|
Voltage
Supply UB
|
24
V DC ±20 %
|
Electricity
input
|
100
mA typ. at wN = 20 m/s and TM = +350 °C
|
Initiation
power
|
140
mA for max. 5 s
|
Settling
time
|
approx.
10 sec. after initiation
|
Connection
|
Connector
(male), M12. 8-pole
|
Pipeline
length (reliable)
|
-
Voltage output
|
|
-
Power output
|
|
-
Digital output
|
|
Analogue
outputs
|
Type
eligible, if demanded
|
-
Function
|
1
flow, 1 temperature
|
-
Type voltage
|
0
... 10 V, RL ≥ 10 kΩ
|
-
Type electricity
|
4
... 20 mA, RL ≤ 400 Ω
|
Digital
output wN
|
pulse
output
high level: ≥ UB - 1.5 V
low level: ≤ 0.7 V
load electricity: ≤ 400 mA
|
Frequency
digital output
|
0
... 10 / 16 / 20 / 40 / 100 Hz (eligible if demanded)
|
Minimum
pulse duration
|
1
/ (2 x fmax)
|
Material
|
|
-
Enclosure
|
aluminum
AlMgSiPb, anodized
|
-
Probe pipe
|
stainless
steel X6 CrNiMoTi 1.4571
|
-
Sensor Head
|
ceramic
|
-
Sensor element
|
platinum
resistance element, glass passivated
|
Fixation
|
brassed
straight coupling,
montage winding G 1/2 x 12
|
Montage
tolerance
|
±3
° relative to flow direction
|
Montage
location
|
eligible
|
Sensor
length (L)
|
400
/ 600 / 1000 mm; relevant sensor length on demand
|
Weight
|
550
g max. (400 mm insert length)
800 g (edition field bus)
|
Protection
type of enclosure
|
IP
65
|
Protection
type of sensor
|
IP
67 (pressure-resistant high temperature edition)
|
1:
lower reference conditions
|
2:
limited in case of air drop flow < 2m/s and simultaneous overload pressure
|
Field
bus DeviceNet-edition (option)
|
Standardization
|
ISO
/ DIS 11 989
DeviceNet Specification volume I + II
Release 2.0
|
Electronic
connection
|
8-pole
screw-type terminal inside enclosure, cable input via 3 cable tunnels
|
Connection
resistance
|
The
connection resistance (120 Ω, 0,25 W) is switched of by the manufacturer
and can be added by connecting a single-pole DIP switch
|
Baud
rate
|
125
/ 250 / 500 kbit/s, default values 125 kbit/s,
adjustable via DIP switch or via software
|
Operating
types
|
Poll
mode, change of state (COS), cyclic
|
Processor
data
|
32
bit, volume flow or flow acceleration eligible
|
Signal
thresholds
|
Upper
and lower signal threshold for flow acceleration and volume flow eligible
|
Warn
flag
|
signalization
at excess of measuring range
|
Alarm
flag
|
Signalization
of sensor defect
|
Status
indicator
|
Duo-LED
indicated status of field bus communication
|
Profi
bus DP-edition (option)
|
Standardization
|
PROFIBUS
standards
EN 50 170
|
Electronic
connection
|
8-pole
screw-type terminal inside the enclosure
cable input via three cable tunnels
|
Connection
resistance
|
The
active termination resistor network (390-220-390 Ω) is turned off by the
manufacturer and can be added by connecting a 2-pole DIP switch
|
Baud
rate
|
9600
Bd - 12 MBd, setting automatically through PROFIBUS-Master
|
Address
|
00
... 99, adjustable via BCD rotary control
|
Operating
types
|
"Data
exchange" depending on PROFIBUS DP-V0
|
Processor
data
|
32
bit; volume flow or flow velocity adjustable
|
Signal
thresholds
|
Upper
and lower signal threshold for flow acceleration and volume flow eligible
|
Warn
flag
|
signalization
at excess of measuring range
|
Alarm
flag
|
Signalization
of sensor defect
|
Status
indicator
|
Duo-LED
indicated status of PROFIBUS communication
|
Delivery
Content
|
1
x precision airflow sensor (relevant edition), 1 x instruction manual
|
Additional
Equipment
|
Welded
sleeves
(item number 524916 (steel) or item nr. 524882 (stainless steel))
|
|
|
|
Similar
products to the Precision Airflow Sensor SS 20.650:
|
|
Here you will find an overview of all the measuring instruments available at PCE Instruments.
|
Contact: PCE Instruments UK Limited
Unit 11 Southpoint Business Park
Ensign Way, Southampton
United Kingdom, SO31 4RF
Phone: +44(0) 23 809 870 30
Fax: +44(0) 23 809 870 39
|
Contact: PCE Americas Inc.
1201 Jupiter Park Drive, Suite 8
Jupiter 33458 FL
USA
Phone: +1-410-387-7703
Fax: +1-410-387-7714
|