High-Pressure Flow Sensor SS 20.60
High-pressure flow sensor for measurements of flow velocities and flow rate /
resistant against pressure up to 16 bar / microcontroller measurement converter / easy construction / digital output / optionally with Fieldbus interface
|
With this high-pressure flow sensor you will be able to measure flow velocities and flow rates of several gases. The high-pressure flow sensor can be delivered in several types. A wide measuring range will be offered through the high pressure flow sensor SS 20.60. Via a temperature range of -20 ºC ... + 120 ºC it is possible to measure flow velocities of 0 ... 200 m/s during a pressure from up to 16 bar. The aerodynamic sensor probe isn't built of movable components. The tolerance of ± 5 ºC will apologize inaccuracy. The sensor is also free of maintenance. The sensor determines the thermal resistance and the flow of volume will convert the measured heat amount into the flow velocity. This measurement principle makes a seperately determination of relative pressure and relative temperature for measurements of norm velocity no more necessary. A digital output makes it possible to connect the high-pressure flow sensor with energy management systems. There are several field of application for the high-pressure
flow sensor SS 20.60. For example combustion control, monitoring exhaust air and measurement of air consumption can be done.
The high-pressure flow sensor is a great allrounder. For further information about the high-pressure flow sensor SS 20.60, please
read the following technical data or call our Hotline:
+44 (0)2380 987030. Our engineers and technicians
will gladly advise you with the Universal air flow sensor SS 20.250 or all other
products
in the terms of regulation
and control, scales
and balances of PCE
Instruments.
|
|
|
- High temperature gradient
- Electric temperature compensation
- Measuring dynamic 1:1000
- Resistant against pressure up to 16 bar
|
- Low weight
- Hard sensor probe
- LED display
- With Fieldbus or PROFIBUS interface
|
Technical data about
high
pressure air-flow
sensor
|
Measure
variable
|
Proper
speed wN based in standard conditions with 20 °C and 1013.25
hPa,
|
Measurement
medium
|
Air
or nitrogen, further gasses on order
|
Measuring
range air flow wN
|
0…1/
2.5/
10/ 20/ 40/ 60/ 120/ 160/ 200 m/s
|
Lower
detection threshold wN
|
0.2
m/s
|
Lower evaluation limit
|
0.1
m/s
|
Measuring
accuracy
|
±
(3 % from
measuring value
+ [0.4 % from measuring range])
|
Reproducability
|
±
0.5 % from
measuring value
|
Response
time t90 wN
|
3 sec. (jump from 0 to 5 m/s
air)
|
Operation temperature
- Compact sensors
- Sensors
- Electric
|
-20
... +85 °C
-20 ... +120 °C
0 ... +60 °C
|
Storage temperature
|
-20
... +85 °C
|
Humidity
|
0
... 95 % RH
|
Operating pressure
- athmospheric
- overpressure
|
700
... 1300 hPa
0 ... 16 bar (compact sensor only)
|
Temperature gradient
|
8
K/min bei wN = 5 m/s
|
Break time
|
6
s bei Temperatursprung
ΔtAir = 40 K bei wN = 5 m/s
|
Temperature dependence
|
compensating
in operating temperature range
|
Pressure dependence
|
independent
from pressure of the medium
|
Zero point correction
|
press-related
flow curve adjustments
|
Voltage supply
|
24
V
DC ±20 %
|
Medium,
environment
|
Non-condensing (up to
95 % RH)
|
Operation
pressure
|
Atmospheric
(700…1300 hPa)
|
Display
|
Duo
LED green/red
|
Voltage
Supply
|
24
V AC/DC ± 10 %, max. 100 mA
|
current
consumption
- standard sensor
- FB sensors
|
75 mA typ. at wN = 0
m/s
140 mA typ. at wN = 200
m/s
250 mA typ. at wN = 160
m/s
|
inrush
current
- standard sensor
- FB-Fühler
|
160
mA for max. 5 s
270 mA for max. 5 s
|
Settling time
|
about
10 s after switching on
|
Electrical connection standard sensor
|
|
Electrical connection
|
Housing
plug-in connector M12, 4 poles including connection cable with plug
4 x 0.34 m²
|
Length of cable (standard)
|
5
m
|
Length of cable (allowed)
- Voltage output
- Current output
- Digital output
|
15 m
100 m
100 m
|
Analog
output
- type voltage
- type current
|
Type
can be selected upon ordering
0 ... 10 V
0
/ 41) ... 20 mA
|
Load
resistance (allowed)
- voltage output
- current output
|
≥ 100 kΩ
≤ 400 Ω
|
Digital
output
|
Pulse
output
High-Level: ≥ UB - 3 V
Low-Level: ≤ 0,7 V
Load resistance: ≥ 2 kΩ
|
Frequency Digital output
(choosable at order)
|
0
... 10 / 16 / 20 / 40 / 100 Hz
(depending on system)
|
Minimum impulse duration
|
min.
1 / (2 x fmax)
|
1)This output type offers an error alarm (error current 2 mA)
|
Other
specifications
|
|
- Casing
- Sensor pipe
- Sensor probe
- Sensor element
|
anodised
aluminium
stainless steel X6 CrNiMoTi 1.4571
Thermoplast PPO/PA
platinum Resistor-Elements
|
Fixation
|
brass
through bolt, pressure tight, movable, mounting threads G1/2 x 12
|
Installation
tolerance
|
±
5 ° relatively to direction of flow
|
Installation position
|
arbitrary,
vertical drop flow increases the lowest Measurement limit to wN = 2 m/s
|
Dimensions
- Casing Standard
- Casing Fieldbus
- Sensor probe
- Sensor pipe
|
67,3 mm x 56,5 mm (Ø x H)
67,3 mm x 103,5 mm (Ø x H)
8 mm x 15,2 mm x 12,5 mm (B x H x T)
15 mm (Ø)
|
Installation Length
- Compact sensors
- Installation sensors
|
120 / 180 / 250 / 400 mm optionally
190 mm , deposed by housing with 3 m connection cable
|
Weight
|
450
g
max. (without cable)
800 g (SS 20.60 FB)
|
Protection
class
|
IP
65 (housing)
IP 67 (sensor)
|
Fieldbus Device Type (optionally)
|
|
Norm
|
ISO
/ DIS 11 898
DeviceNet Specification Volume I + II
|
Electric connection
|
8
pole screw connector on inside of the housing
cable feeding via 3 cable bushings
|
Connection resistance
|
connection resistance
(120 Ω, 0,25 W) is factory set off and can be enabled by a DIP-Switch or
Software
|
Baud rate
|
125
/ 250 / kbit/s, Defaultvalue 125 kbit/s, adjustable via DIP-switch or Software
|
Adress
|
0
... 63, Defaultvallue Adress 63 (MAC ID 63), adjustable
via DIP-switch or Software
|
Operation
Type
|
Poll
mode, Change of State (COS), cyclic
|
Processdata
|
32
bit, Volumeflow respectively Flowspeed selectable
|
Automatic
threshold
|
High
and low threshold for flow speed and volumeflow adjustable
|
Warning
Flag
|
signalling
when values exceed the measuring range
|
Alarm
Flag
|
Signalling
a sensordefect
|
Status
display
|
Duo-LED
shows state of fieldbuscommunication
|
PROFIBUS DP-Type (optionally)
|
|
Norm
|
PROFIBUS
Norm
EN 50 170
|
Electric connection
|
8
pole screw connector on inside of the housing
cable feeding via 3 cable bushings
|
Connection resistance
|
connection resistance
(390-220-390 Ω,) is factory set off and can be enabled by a 2-pole
DIP-Switch or Software
|
Baud rate
|
9600
Bd - 12 MBd, setiing automatically by PROFIBUS-Master
|
Adress
|
0 ... 99, adjustable
via BCD turn-switch
|
Operation
Type
|
"Data
Exchange" with PROFIBUS DP-V0
|
Processdata
|
32
bit, Volumeflow respectively Flowspeed selectable
|
Automatic
threshold
|
High
and low threshold for flow speed and volumeflow adjustable
|
Warning
Flag
|
signalling
when values exceed the measuring range
|
Alarm
Flag
|
Signalling
a sensordefect
|
Status
display
|
Duo-LED
shows state of PROFIBUS-communication
|
Delivery content high-pressure flow sensor SS 20.60
|
1 x high-pressure flow sensor (depends on type), 1 x manual description
|
Purchasable
equipment
for universal
air flow
sensor
|
Welded
sleeve (art. nr. 524916 (steel) or art. nr. 524882 (stainless
steel)
|
|
Through
bolt made of stainless steel (art. nr. 511958) to 16 bar Overpressure, with
protection of pressure
|
|
|
|
In the following, you can see more products in the field of High Pressure
Air-Flow Sensors |
|
Here you will find an overview of all the measuring instruments available at PCE Instruments.
|
Contact: PCE Instruments UK Limited
Unit 11 Southpoint Business Park
Ensign Way, Southampton
United Kingdom, SO31 4RF
Phone: +44(0) 23 809 870 30
Fax: +44(0) 23 809 870 39
|
Contact: PCE Americas Inc.
1201 Jupiter Park Drive, Suite 8
Jupiter 33458 FL
USA
Phone: +1-410-387-7703
Fax: +1-410-387-7714
|
This page in German
in Italian
in Spanish
in Croatian
in French
in Hungarian
in Turkish
in Polish
in Russian
in Dutch
and in Portuguese
|